background image

Made

in France

Manual ref: 1895306

Edition n°: 15.342

User instruction manual

Edel

 AIR

Air source Heat Pump Water Heater

for outdoor air or non-heated ambient air

Edel A

ir 200 

and 270 liters

The domestic hot water heater mainly operates using the integrated heat pump, as long as the air intake 
is within the -7°C to 35°C temperature range.

A 1.5kW electrical backup function ensures comfort at all times, and particularly in the following cases:

- air taken in outside the operating range.

- minimum comfort function: when this function is activated, both means of heating (heat pump and 

electrical backup) operate at the same time to ensure that the water temperature remains above 
38°C.

- “Boost” function: when this function is activated, both means of heating (heat pump and electrical 

backup) operate at the same time to reach the desired temperature quickly.

Depending on how many people are using the water and to optimise savings, we would advise you not 
to set the default temperature too high (

for example at 50°C).

 ..... Compressor activated

.... Fan activated

 ........ De-icing in progress

 ........ Electrical  backup 

activated

 .... Domestic hot water 

request

 ....... Economy mode 

activated

 ....... Freeze protection mode 

activated

 ...... Holiday mode activated

1 - Control box

Pictograms:

3

4

5

1

2

1

 Display screen

2

 Dial

3

 Menu

4

 On/off 

5

 Time setting

  

The information contained in this documant is non-contractual. 

Auer reserves the right to change technical data and equipmen

t of all appliances without prior notice.

Содержание Edel Air 200

Страница 1: ...ensure that the water temperature remains above 38 C Boost function when this function is activated both means of heating heat pump and electrical backup operate at the same time to reach the desired temperature quickly Depending on how many people are using the water and to optimise savings we would advise you not to set the default temperature too high for example at 50 C Compressor activated Fa...

Страница 2: ...iod the heat pump water heater shows RETURN on the display screen as well as a countdown of the days Holiday mode puts the appliance on standby whilst the freeze protection mode remains active This function can be programmed to run between 1 and 99 days and is effective as soon as the number of days has been confirmed Set number of days in standby mode 5 Electric mode to operate with electrical ba...

Страница 3: ...or 3 seconds Enter Select yes 500 C unlock no Press for 3 seconds Enter Select yes 500 C Unlock no Unlock Yes Appui 3 sec Press for 3 seconds Locking 9 Programming Press Clock settings and hold down for 3 seconds Copy programming from day before Copy a standard programme or a programme from another day Modify existing programme See existing programme Set end of first time period Set comfort level ...

Страница 4: ...ssure too low Insufficient airflow Air inlet outlet blocked Air vent duct blocked Ventilateur bloqué ou HS Evaporator clogged or blocked Evaporator iced over Check fan is running Check that air is circulating properly throughout the piping circuit Check pipe lengths 10m max flexible hose 20m max rigid pipes Check any filters on air ducts Check that evaporator is clean Heat pump non functional Elec...

Отзывы: