EDEL 270 AIR DE/2

Heat pump water heater

using exterior air or non-heated ambient air

WITH THERMAL HEAT EXCHANGER

1 - Présentation

1.1 - Dimensions

Domestic hot water outlet (DHW)
M3/4G

Domestic cold water inlet (DHW)
M3/4G

1780

  -  Domestic Hot Water outlet (DHW) 3/4’’

  -  Domestic Cold Water inlet (DCW) M3/4’’

  -  Air exhaust Ø160

  -  Air intake Ø160

  -  Heat exchanger inlet M3/4’’ 

 

  (Max. temperature = 95°C)

  -  Heat exchanger outlet M3/4’’

Bulb well for domestic water sensor

Содержание Edel 270 AIR DE/2

Страница 1: ...their appliances without prior notice EDEL 270 AIR DE 2 Heat pump water heater using exterior air or non heated ambient air WITH THERMAL HEAT EXCHANGER 1 Présentation 1 1 Dimensions Domestic hot water outlet DHW M3 4G Domestic cold water inlet DHW M3 4G 1780 Domestic Hot Water outlet DHW 3 4 Domestic Cold Water inlet DCW M3 4 Air exhaust Ø160 Air intake Ø160 Heat exchanger inlet M3 4 Max temperatu...

Страница 2: ...HW Boiler Domestic cold water DCW Outlet Inlet Boiler outlet Boiler inlet Bulb well for domestic water sensor or domestic water aquastat for boiler D For the domestic water connection diagram refer to the installation manual of the appliance 1 2 Performances technical characteristics 2 1 Installation diagram 2 2 Use of the primary heat exchanger to couple a boiler by using the heat pump water heat...

Страница 3: ... brown blue blue grey grey black pink brown FAN green yellow red blue BOILER AQUASTAT INPUT 2 3 Electrical connection with primary heat exchanger for coupling to a boiler HP High pressure pressure switch C15 Compressor start up capacitor C2 1 5µF fan capacitor C4 4µF fan capacitor EV De icing valve RE 1500W electrical resistance LTS Electrical back up temperature limiting safety thermostat AqL Ele...

Страница 4: ...PEED 2 If the heat pump water heater is connected using pipes it is necessary to adjust the fan speed to allow for the heat pump to overcome heat losses caused because of the air connections Changing of the fan speed can be done using the electrical terminal of the appliance The grey wire must be moved connecting the 11B output on the circuit board to the 5 5µF capacitor to the double input on the...

Отзывы: