INSTALLATION
DS170 PILOT
MANUAL
-
21
6.4 - List of parameters which can be set
Parameter N°
Description
Unit
Range of setting
Factory
setting
P202
Maximum exterior temperature (TEMA)
°C
11
to
25
20
P203
Minimum exterior temperature (TEMI)
°C
-
30
to
10
-
5
P204
Summer/winter changeover: choice of changeover method
-
auto
: changeover is done automatically based on the
exterior temperature
manu
: changeover is done manually by the user
manu
P205
Summer/winter time delay: time period for observation
of the exterior temperature before automatic season
changeover. Only used if automatic changeover is activated.
hour
0
to
48
12
P206
Reactivity: the temperature for heating takes into account
the ambient temperature to accelerate heating time when
heating is switched on or restarted.
-
yes
: reactivity activated
no
: reactivity deactivated
no
P207
Anticipation of heating: heating restarted before return
from holidays (for a home already at the set temperature on
return)
-
yes
: anticipation activated
no
: anticipation deactivated
no
P208
Minimum exterior temperature for operation using only the
HP (TEPAC).
The back-up is authorised to operate in colder temperatures.
°C
P209
to
20
2
P209
Maximum exterior temperature for operation using only the
back-up (TEAPP).
The heat pump is authorised to operate in warmer
temperatures.
°C
-
20
to
P323
-
20
P210
Operation during peak hours (when pilot receive an open
contact on HP/HC terminal)
-
0
: no operation
1
: heat pump 1st power stage authorized
2
: heat pump 2nd power stage authorized
3
: heat pump 3rd power stage authorized
4
/
5
/
6
: full authorization (heat pump + electric back-up)
7
: 3kW electric back-up only
8
: room comfort set on anti-freeze level
9
: room comfort set on eco level
10
: PV-smart grid control
6
P211
Operation during shedding (when pilot receive an open
contact on shedding terminal)
-
0
: no operation
1
: heat pump 1st power stage authorized
2
: heat pump 2nd power stage authorized
3
: heat pump 3rd power stage authorized
4
/
5
/
6
: full authorization (heat pump + electric back-up)
7
: 3kW electric back-up only
6
P212
Type of back-up
-
no
: no backup
Elec
: Electrical back-up
no
P213
Heat pump time-out: allows the heat pump to continue
running for a period of time after intervention of the back-
up
min.
1
to
20
5
P214
Diff erence in temperature between the back-up and the
heat pump
°K
0
to
7
4
P215
Presence of a heat pump
-
0
: operation without a heat pump
1
: presence of a heat pump
1
P216
to
p226
Not concerned
-
Do not change the setting
0.5
P221
Choice of compressor in operation
-
0
to
2
0
P227
Speed of heat pump circulator pump
%
10
to
100
100
P228
Post-circulation of the heat pump circulator pump
-
Do not change the setting
3
P230
Speed of heating circuit circulator pump
%
10
to
100
100