background image

128-8534

1 of 8

Model  APS-25N

Installation Manual

Note :

 When both Passive Arming and Voltage Sensing are selected, you must hardwire the driver’s door pin switch

in order to begin the passive arming sequence.

RF Programmable Features :

Feature Selection

1 Chirp

2 Chirps

3 Chirps

4 Chirps

Default

1st Door L/UL

1 Sec.

    3.5 Sec.

   1 Sec L, Dbl. U/L

1 Sec.

2nd Accy Lock

Auto Lock On

    Auto Lock Off

Auto Lock Off

3rd Accy. UL

Auto UL On

   Auto UL Off

Auto UL Off

4th Passive Locks

Passive

    Active

Active

5th Passive/Active Arm

Passive  Arm

    Active Arm

Active Arm

6th Voltage Sense

Voltage  Sense     Hardwire

Hardwire

To program these selectable features;

Action

System Response

Turn ignition on

No  response

Press and release the valet switch 3 times

1 Chirp - LED 1 flash

Within 3 seconds, turn ignition Off

Short chirp, then long chirp

First

Then On

1 chirp = 1 second door locks

Press transmitter Lock button to change

2 chirps = 3.5 second door locks

Press transmitter Lock button to change

3 chirps = 1 sec. lock, dbl 1 sec. unlock

o r

Second

Press and release the valet switch

2 chirps = auto locks off

Press transmitter Lock button to change

1 chirp = auto locks on

o r

Third

Press  and release the valet switch

2 chirps = auto unlock off

Press transmitter Lock button to change

1 chirp = auto unlock on.

o r

Fourth

Press and release the valet switch

2 chirps = active locks

Press transmitter Lock button to change

1 chirp = passive locks

o r

Fifth

Press and release the valet switch

2 chirps = active arming

Press transmitter Lock button to change

1 chirp = passive arming

o r

Sixth

Press and release the valet switch

2 chirps = hardwire

Press transmitter Lock button to change

1 chirp = voltage sense

o r

Turn ignition key off

Exit program mode

Note:

Once you enter the feature programming mode, do not allow more than 30 seconds to pass between steps, or the
programming will be terminated.