background image

10

 

5  Usage 

5.1  Powering up 

First  of  all,  please  make  sure  your  EPS  is  connected  correctly  to  the 
mother unit and the mains (see section '

Mains connection

' on page 8 and 

'

Connecting the mother unit

' on page 9). 

The  EPS  is  a  stand  by  unit.  Please  operate  the  mains  switch   1   on  the 
back panel to put the EPS in stand by mode. 

Only in cases of extended absence (like vacations) or if massive trouble 
on  the  mains  power  is  to  be  expected  (e.g. thunder  storms)  it  is  recom-
mended  to  disconnect  the  EPS  from  the  mains.  To  disconnect  the  EPS 
from  mains  completely,  you  have  to  pull  the  mains  cord  off  the  mains 
jack  2 . 

 

 

Important

 

·

 

Never  pull  the  mains  cord  while  the  EPS  or  the  mother  unit  is 
switched  on!  Before  you  pull  the  mains  plug,  power  down  the 
mother unit to stand-by mode and switch off the EPS on the back 
panel. 

 

 

5.2  Switching on/off 

Please operate the mains switch   1  on the back panel to put the EPS in 
stand by mode.  

The  position  of  mains  switch  of mother  devices  that  need  no  additional 
mains connection (see section '

Connecting the mother unit'

 on page 9) is 

negligible. All other mother devices must be switched on.  

Now operate the mother device as usual, all functions are the same. If the 
mother  device  is  switched  on,  the  LED  on  the  EPS  front  panel  is  acti-
vated.  

If you switch off the mother device, the power LED of the EPS turns off. 

 

 

Note 

·

 

For  further  information  on  starting  up  a  mother  device  with  5-pin 
connector in combination with an EPS please consult the user's man-
ual of the mother device. 

Содержание EPS

Страница 1: ...1 Enhanced Power Supply User s Manual ...

Страница 2: ...2 ...

Страница 3: ...w front panel 6 3 Overview back panel 7 4 Installation and connection 8 4 1 Placement 8 4 2 Mains connection 8 4 3 Connecting the mother unit 9 5 Usage 10 5 1 Powering up 10 5 2 Switching on off 10 6 Technical Information 11 7 Security advice 12 8 Technical data 13 ...

Страница 4: ...th the external power supply EPS you have the possibility to give all connected units a more sophisticated fundament Please read this manual before first use to make sure that you are able to use all provided functions of your new unit In case of occurring ques tions please do not hesitate to contact your local Audionet dealer or our factory directly ...

Страница 5: ...cable one standard mains cord 1 2 Transport Important Please transport the EPS only in the included package Always use the plastic bag to prevent scratches on the casing Please allow the EPS to adapt to the climatic conditions in your lis tening room before you switch on the unit for the first time after transport If the mother unit has a 5 pin EPS socket ...

Страница 6: ...6 2 Overview front panel LED power indicator ...

Страница 7: ...7 3 Overview back panel 1 Mains switch 2 Mains input 3 Marking mains phase 4 7 pin connector 1 4 3 2 ...

Страница 8: ... the EPS on top of other units especially not on top of power amplifiers pre amplifiers or similar that produce heat Both units could suffer damage from thermal overload Do not use the unit in places where it is exposed to vibrations Do not place the unit close to loudspeakers or into the corner of a room where it is exposed to high levels of sonic energy which might reduce the sound quality of th...

Страница 9: ...using the mains switch 1 To disconnect the unit completely from mains pull the mains plug 4 3 Connecting the mother unit For the connection of the mother unit an EPS cord with 5 pin or 7 pin connector is needed An overview can be found in the following table EPS cord with 5 pin connector EPS cord with 7 pin connector Image of the connector Mother unit PRE 1 G3 VIP VIP G2 VIP G3 ART ART V2 ART G2 A...

Страница 10: ...he EPS or the mother unit is switched on Before you pull the mains plug power down the mother unit to stand by mode and switch off the EPS on the back panel 5 2 Switching on off Please operate the mains switch 1 on the back panel to put the EPS in stand by mode The position of mains switch of mother devices that need no additional mains connection see section Connecting the mother unit on page 9 i...

Страница 11: ...tput voltage ripple at the same load fluctuations The output voltage is not long term stable The output voltage of an accu mulator is highly dependent from its state of charge and usage his tory typically ranging from 23 to 28 Volts The EPS always provides 24 00V The usage of accumulators is questionable regarding to environ mental concerns Last not least you are able to listen to your music with ...

Страница 12: ...re and operate the unit in a dry room at a reasonable room tem perature only Avoid moisture any liquids dirt or small objects getting into the unit Set up the unit in a sufficiently ventilated environment Do not cover the unit Do not open the unit Unauthorised opening will void warranty Use dry cloth for cleaning ...

Страница 13: ...ility 0 01 V at 0 5 A Noise 144 dB or 1 5 mVeff at 0 Hz to 22 kHz Mains 230 V 50 60 Hz Power consumption Stand by 0 5W max 40 Watt Dimensions Width 430 mm Height 70 mm Depth 310 mm Weight 9 kg Finish Front 10mm brushed aluminium black anodised white print or 10mm aluminium nature anodised black print Cover aluminium black anodised 2 mm Chassis steel black coated 2 mm Errors and omissions excepted ...