USER MANUAL
Version 1.1
2016
Страница 1: ...USER MANUAL Version 1 1 2016 ...
Страница 2: ...RNING DANGEROUS VOLTAGES ARE PRESENT IN THIS MACHINE AND CONTROLLER WHEN ELECTRICAL POWER IS APPLIED THERE IS A DANGER OF INJURY FROM ELECTRIC SHOCK UNDER NO CIRCUMSTANCES ARE YOU TO ATTEMPT TO OPEN THE MACHINE AND CONTROLLER OR ATTMPT TO REMOVE OR ADJUST ANY COMPONENTS FITTED WITHIN THE MACHINE AND CONTROLLER ONLY FULLY TRAINED SERVICE ENGINEERS ARE QUALIFIED TO OPEN THE MACHINE AND CONTROLLER Ca...
Страница 3: ...MACHINE Cleaning PLEASE INSPECT FOUNTAIN NOZZEL OF SPARKULAR MACHINE BEFORE USE AND CONFIRM WHETHER THERE ARE ACCUMULATED GRANULES PLEASE CLEAN OUT EXCESS BY INVERTING THE UNIT TO CLEAN OUT PORT EACH TIME BEFORE THE UNIT IS FIRED AND WHEN DONE BING USED THE CLEAR MATERIAL FUNCTION SHOULD BE USED TO PROLONG MACHINE LIFE THE FOUNTAIN PORT CAN BE CLEANED WITH S BOTTLE BRUSH IF NECESSARY Power Supply ...
Страница 4: ...e 1 Sparkular Operation Panel Page 2 to Page 3 Interface Page 3 to Page 5 DMX Channel Mode Page 5 Host Controller ZK 6200 Page 6 Controller Operation Panel Page 7 to Page 12 System Configuration and Connection Page 13 to Page 14 System Prepare and Start Page 15 to Page 17 End Notes for the Repeat Period Page 18 ...
Страница 5: ...r DMX console is used the read out function for the console will not be able to be used The following descriptions will help to learn the operation and function of the working of both the Sparkular head and the host controller 3 Brief Introduction of the Functions a The Controlling Signal of International Standard DMX 512 b Fixture uses Two Channels Channel 1 controls effect height 2 controls the ...
Страница 6: ...to affect its cooling or impede the operation of the fountain Do not place anything on sides or top that would impede cooling 3 If find fountain becomes small please add Sparkular Granules 5 Operation Panel a LCD information display area showing action menu and operating status of the equipment b LED Displaying Area READY Flashing shows that the system is preparing Solid Light shows that the syste...
Страница 7: ...otor Protect Over current protection of the motor E2 Temp Sensor Temperature sensor is not connected or be damaged E3 P Temp Over The equipment stops due to the over temperature of the chassis E4 Time Remain The Sparkular Grain materials are about to run out E5 K Temp Over The equipment stops due to over temperature of the mechanism E6 Heating Failure Perhaps some issues for heating system Please ...
Страница 8: ... density 3 Density Height 4 30 60 Adjusts the Value of the Granular feed or density 4 Density Height 5 30 70 Adjusts the Value of the Granular feed or density 5 Density Height 6 40 100 Adjusts the Value of the Granular feed or density 6 Density Height 7 40 100 Adjusts the Value of the Granular feed or density 7 Density Height 8 40 100 Adjusts the Value of the Granular feed or density 8 Density Hei...
Страница 9: ...1 40 63 Fountain Height 2 64 87 Fountain Height 3 88 111 Fountain Height 4 112 135 Fountain Height 5 136 159 Fountain Height 6 160 183 Fountain Height 7 184 207 Fountain Height 8 208 231 Fountain Height 9 232 255 Fountain Height 10 Second Channel Function 60 80 Clear Material 20 40 EMERGENCY STOP 0 10 Pre heat Off 240 255 Pre heat On ...
Страница 10: ...rnet not currently available for future application Support max 200m communication cable 3350mAH battery Lifetime 3 years 2 Host Controller Introduction Standard or Pro Version a International standard DMX512 signal output b Support 18 units Sparkular at the same time Standard 18 units Pro Controller 54 units c Five kinds of standard Dynamic modes Synchronization All Fire Center to Ends Ends to Ce...
Страница 11: ... Input Port of Main Channel Aux Audio Signal Socket of Side Channel Music Displaying the Electrical Level of Audio Signal MIDI In Time Synchronous Signal Input of MIDI thru output DMX 512 DMX Signal Options top Output bottom Input for DMX console control LAN Network s Cascade Socket among Multi Chassis so as to link the remote control feature Download SparkularEdit200 soft Port ...
Страница 12: ...minate Red Firing will occur when the Fire button is initiated The Sparkular will stop automatically after 30 seconds if not shut off c Mode Selection Area There are five standard dynamic modes and one special effects mode which can be initiated by pressing the keys These activate a pre programmed page of functions that are displayed on each selection They can be manually added Manual operation wi...
Страница 13: ... long distance transportation the granules can be dislodged into the heating tube it can be cleared by pressing this key so as to have a uniform operation of the device Pre heat Before starting up Sparkular the pre heat function should be turned on first and Sparkular units can be fired only when the system shows a ready solid green light within 5 minutes If the DMX is unplugged or communication i...
Страница 14: ...r repeat counts Terminal Monitor These are displayed in a table that is in F1 and below the play back file selected These display the working status of Sparkular will be displayed in corresponding areas and the number is the trigger temperature of Sparkular There are 1 18 on the Standard Controller and 3 sets of 18 or 54 units that are displayed in rotational sequence The standard operating temper...
Страница 15: ...t of the 8 files that can be set to the height duration time between shots and the time until the next firing Loops can be created and repeated up to 5 times per file in the count column In this way you can select the needed files quickly D Configuration Menu F3 ...
Страница 16: ...nits are set to low to high LAN Communication Port This port is for future Communication 5 The Use of the Special Effect Mode With the USB cable connected to the computer the download can be completed through Sparkular Edit 200 soft so you can follow the User s Guide of Sparkular Edit 200 in detail See Console operation manual Trigger Source Options when Trigger Source is selected as HAND the file...
Страница 17: ...back track has been interrupted The program would need to be paused or stopped by the operator and restarted to resume operation of the Sparkular show Once again the Pre Heat function will turn off and would need to be reset to on position 3 System Configuration and Connection 1 System Configuration Sparkular Standard DMX Communication Cable 2 1 4 3 5 6 Host Controller AC Input 3PIN Power Supply C...
Страница 18: ...Cable Maximum of 6 units Sparkular in series with the Main power supply cable Sparkular BT01 BT02 Power Con Main Cable c Power Supplier Cable Connection between Sparkular Sparkular BT01 BT02 Power Extension Supply Cable Sparkular BT01 BT02 d Communication Cable Connection between Sparkular Sparkular BT01 BT02 DMX Communication Cable Sparkular BT01 BT02 ...
Страница 19: ...e are 3 styles of the Granular material 1 Small 2 Medium and 3 Large These are a variety of height and density They range from 1 5m to 5m in height Small Medium Large Fountain Height 1 5m 3m 1 5m 3 5m 2m 5m a Open the Sparkular Granule material pouch 1 Small 2 Medium 3 Large b To fill in the Sparkular Granules with tooling Open cover Tooling Fill in Granule material Close cover Warning Please foll...
Страница 20: ...effects Sparkular Edit200 soft is designed for ZK6200 and can program lots of special effect 5 Activate Sparkular machine An RFID Card is needed to activate the Sparkular by scanning the defined area closely Once activation successful the remaining use time of the machine will be displayed on the screen approximately 20 minutes When the remaining use time is less than 10 minutes E4 will be display...
Страница 21: ...thing into the Fountain Port Nozzle HOT SURFACE 8 Clear Granular material The Clear material function should be used after each time the units are used and show is finished To prepare for proper storage after powering off Sparkular and controller please pour consumptive materials from material fill port with tooling If using frequently this does not need to be done each time Tooling To empty Granu...
Страница 22: ...he Repeat Period value needs to be higher than the Firing Duration for the Synchronize mode or the total time of the duration plus trigger delay can be used to create a wave style effect Please note that the Sparkular units are not made to run continuously or for long periods of time It has a maximum of 60 90 second intervals Its standard usage is for programmed sequences for up to 90 seconds The ...