Version 5.4
55
May 2008
SIP Hardware Installation Manual
3. Installation
¾
To connect the OAMP and Control network interfaces, take these 3
steps:
1.
For each network type, connect a standard Category 5 network cable to the required
Ethernet RJ-45 port (as described above) on one of the PEM modules.
2.
Connect the other end of the Category 5 network cable to your IP network.
3.
For Ethernet redundancy/backup, repeat steps 1 through 2 for the corresponding
Ethernet port on the second PEM module.
The RJ-45 connectors are wired according to the figure below:
Figure
3-11: RJ-45 Connector Pinouts
3.3.3.3 Connecting GbE Interfaces to IP Network
The RTM-8410 provides two Gigabit Ethernet (GbE) interface ports (RJ-45 connectors).
The dual ports support 1+1 Ethernet redundancy. These ports are used for interfacing with
the IP network (LAN). The status of these ports are indicated by the
GBE
LEDs on the
8410 blade in the chassis' front panel (refer to ''LEDs'' on page
Notes:
•
For IPmedia 3000, the RTM-8410 providing two SCSI ports is
implemented. However, only the GbE interface ports are used.
•
For Mediant 3000 in HA mode, both RTM-8410's must be separately
cabled to the IP network (using the GbE interface ports). When in
Simplex mode and using two RTM-8410s (i.e., for 84 E1/T1), only the
RTM-8410 in Slot #2 must be cabled to the IP network.
•
Two RTM-8410s are provided for Mediant 3000 with 8410 blades for 42
and 84 spans Simplex and HA modes. Therefore, in an HA system and to
provide full Ethernet redundancy, it is recommended to connect all four
Ethernet ports to the external IP network. In addition, to provide Ethernet
switch redundancy, the two Ethernet ports on each RTM-8410 must be
connected to different switches.
•
When Mediant 3000 with 8410 blade is configured for Physical Network
Separation, the GbE port is used only for interfacing with the Media
network. The connection to the Control and OAMP network interfaces is
performed on the PEM modules (refer to ''Connecting Ethernet Interfaces
to OAM and Control IP Networks'' on page
). When Physical Network
Separation is disabled, the RTM-8410's GbE port is used for all traffic
(i.e., Media, Contraol, and OAM).
Содержание TP-6310
Страница 1: ...Document LTRT 94701 May 2008 Hardware Installation Manual Version 5 4...
Страница 2: ......
Страница 10: ...SIP Hardware Installation Manual 10 Document LTRT 94701 3000 Series Gateways Media Servers Reader s Notes...
Страница 42: ...SIP Hardware Installation Manual 42 Document LTRT 94701 3000 Series Gateways Media Servers Reader s Notes...
Страница 70: ...Hardware Installation Manual Version 5 4 www audiocodes com...