Version 5.8
427
October 2009
SIP User's Manual
6. Configuration Parameters Reference
6.16.2 Fax and Modem Parameters
The fax and modem parameters are described in the table below.
Table
6-54: Fax and Modem Parameters
Parameter
Description
Web: Fax Transport Mode
EMS: Transport Mode
[FaxTransportMode]
Fax transport mode used by the device.
[0]
Disable = transparent mode.
[1]
T.38 Relay = (default).
[2]
Bypass.
[3]
Events Only.
Note:
This parameter is overridden by the parameter
IsFaxUsed. If the parameter IsFaxUsed is set to 1 (T.38
Relay) or 3 (Fax Fallback), then FaxTransportMode is always
set to 1 (T.38 relay).
Web: Fax Relay Enhanced
Redundancy Depth
EMS: Enhanced Relay Redundancy
Depth
[FaxRelayEnhancedRedundancy
Depth]
Number of times that control packets are retransmitted when
using the T.38 standard.
The valid range is 0 to 4. The default value is 2.
Web: Fax Relay Redundancy Depth
EMS: Relay Redundancy Depth
[FaxRelayRedundancyDepth]
Number of times that each fax relay payload is retransmitted
to the network.
[0]
= No redundancy (default).
[1]
= One packet redundancy.
[2]
= Two packet redundancy.
Note:
This parameter is applicable only to non-V.21 packets.
Web: Fax Relay Max Rate (bps)
EMS: Relay Max Rate
[FaxRelayMaxRate]
Maximum rate (in bps), at which fax relay messages are
transmitted (outgoing calls).
[0]
2400 = 2.4 kbps.
[1]
4800 = 4.8 kbps.
[2]
7200 = 7.2 kbps.
[3]
9600 = 9.6 kbps.
[4]
12000 = 12.0 kbps.
[5]
14400 = 14.4 kbps (default).
Note:
The rate is negotiated between the sides (i.e., the
device adapts to the capabilities of the remote side).
Web: Fax Relay ECM Enable
EMS: Relay ECM Enable
[FaxRelayECMEnable]
Determines whether the Error Correction Mode (ECM) mode
is used during fax relay.
[0]
Disable = ECM mode is not used during fax relay.
[1]
Enable = ECM mode is used during fax relay (default).
Web: Fax/Modem Bypass Coder
Type
EMS: Coder Type
[FaxModemBypassCoderType]
Coder used by the device when performing fax/modem
bypass. Usually, high-bit-rate coders such as G.711 should be
used.
[0]
G.711Alaw= G.711 A-law 64 (default).
[1]
G.711Mulaw = G.711
μ
-law.
Содержание mediapack MP-500
Страница 1: ...Document LTRT 12801 October 2009 User s Manual Version 5 8...
Страница 2: ......
Страница 22: ...SIP User s Manual 22 Document LTRT 12801 MP 500 MSBG Reader s Notes...
Страница 24: ...SIP User s Manual 24 Document LTRT 12801 MP 500 MSBG Reader s Notes...
Страница 290: ...SIP User s Manual 290 Document LTRT 12801 MP 500 MSBG Reader s Notes...
Страница 440: ...SIP User s Manual 440 Document LTRT 12801 MP 500 MSBG Reader s Notes...
Страница 564: ...SIP User s Manual 564 Document LTRT 12801 MP 500 MSBG Reader s Notes...
Страница 566: ...SIP User s Manual 566 Document LTRT 12801 MP 500 MSBG Reader s Notes...
Страница 573: ...Version 5 8 573 October 2009 SIP User s Manual 13 Technical Specifications Reader s Notes...
Страница 574: ...User s Manual Version 5 8 www audiocodes com...