Safety Precautions 

 

The device must be installed and serviced only by qualified service personnel. 

 

The device is considered as IPX0 non-water ingress protected and therefore, must be installed only 

indoors.  

 

Do not expose the device to water or moisture. 

 

Ethernet cabling must be shielded and routed only indoors, and must not exit the building. 

 

Do not open or disassemble this device. The device carries high voltage and contact with internal 

components may expose you to electrical shock and bodily harm.  

 

Make sure the device is installed in a well-ventilated location to avoid over heating of internal 

components and subsequent damage. 

 

Do not place any object on top of the device and make sure that sufficient clearance from the top and 

sides are maintained to ensure proper airflow to avoid over heating of internal components. 

 

Operate the device in an ambient temperature (Tma) that does not exceed 40°C (104°F).  

 

The device must be installed only in restricted access locations that are compliant with ETS 300 253 

guidelines where equipotential bonding has been implemented. 

 

The device includes an integrated secondary surge protection, but does 

not

 provide primary telecom 

protection! When the FXS telephone lines are routed outside the building, additional protection - 

usually a 350V three-electrode Gas Discharge Tube (GDT) as described in ITU-T K.44 - 

must

 be provided 

at the entry point of the telecom wires into the building (usually on the main distribution frame / MDF), 

in conjunction with proper grounding. The center pin of the GDT (MDF grounding bar) must be 

connected to the equipotential grounding bus bar of the Telecommunication room. 

 

Operate the device only from the type of power source indicated on the chassis. 

 

Installation of the device must be in accordance with national electrical codes and conform to local 

regulations.  

 

AC power: Use only the supplied AC power cord for connection to the AC power source. 

 

AC power: The device must be connected to an electrical socket-outlet providing a protective earthing 

connection. 

 

AC power: If you are using both Power Supply modules, connect each one to a different AC power 

supply source. The two AC power sources must have the same ground potential. 

 

DC power: Connect the device to a safety extra-low voltage (SELV) source that is sufficiently isolated 

from the mains. 

 

DC power: Connection of the device to the DC mains power must be done only by a certified electrician 

and in accordance with local national electrical regulations. 

 

DC power: Both Power Supply modules must be connected. Ensure that you connect each one to a 

different DC power supply source. 

 

DC power: The two DC power sources must have the same ground potential. 

 

Содержание MediaPack 1288

Страница 1: ...nd Hardware Manual respectively which can be downloaded from AudioCodes website at https www audiocodes com library technical documents Before you begin please read the Safety Precautions on page 9 Pa...

Страница 2: ...mal device and FXS blade operation Orange On At least one DSP has reached high temperature threshold Red On Initial power up stage or Failure detected in at least one FXS blade or No FXS blade detecte...

Страница 3: ...Supply module s fan is operating normally Orange Flashing Connected to power source but chassis not receiving power or fault detected in Power Supply module s fan If only one of the Power Supply modu...

Страница 4: ...rackets are flush against the front rack posts and that the holes of the front mounting brackets are aligned with the holes on the front rack post 4 Hold the chassis in position while the second perso...

Страница 5: ...e lug to the chassis using the two screws and spring washers For more information refer to the device s Hardware Manual Connect the other end of the strap to protective earthing This must be in accord...

Страница 6: ...to the DC terminal block plug supplied making sure that the wires are inserted in to the correct openings on the terminal block according to their polarity negative or positive Insert the DC terminal...

Страница 7: ...t cable connect any one of Ethernet ports of the CPU module rear panel to the LAN port of your computer 2 Change the IP settings of your computer to correspond with the device s default IP address and...

Страница 8: ...ace s toolbar click the Save button the new IP address is now saved to the device s flash memory 10 Re cable the device to the required network You can now access the device s management interfaces re...

Страница 9: ...the building additional protection usually a 350V three electrode Gas Discharge Tube GDT as described in ITU T K 44 must be provided at the entry point of the telecom wires into the building usually...