Performance Monitoring and Alarms
84
Document #: LTRT-32111
Mediant 3000 with TP-6310
3.2.13
Security Event
Security Event
Textual Description
This event is generated when a specific user is blocked after reaching
the maximum number of login attempts, or when the EMS failed to
sync EMS and Mediant 5000 / 8000 users.
SNMP OID
acEMSSecurityEvent - 1.3.6.1.4.1.5003.9.20.3.2.0.24
AlarmTitle
[Event] Security Event
ItuAlarmType
Other
AlarmSource
EMS Server / User Name,
EMS Sever / User Sync
Probable Cause
Other
Severity
Indeterminate
Additional Info
Corrective Action
Media Gateways
3.2.14
Topology Update Event
Topology Update Event
Textual Description
This event is issued by the EMS when a Gateway or Region is
added/removed/updated in the EMS application and includes the
following information:
Action: Add / Remove / Update GW or Region
Region Name
GW Name
GW IP
Note: For opening an EMS client in the MG context, the gateway IP
address should be provided.
SNMP OID
acEMSTopologyUpdateEvent - 1.3.6.1.4.1.5003.9.20.3.2.0.25
Alarm Title
[Event] Topology Update
Alarm Source
EMS Server
Severity
Indeterminate
Alarm Type
Other
Probable Cause
Other