Performance Monitoring and Alarms
16
Document #: LTRT-32111
Mediant 3000 with TP-6310
2.3
Frame: Fiber Group Monitoring (Real-Time)
2.3.1
Tab: Fiber Group Statistics
Frame: Fiber Group Monitoring (Real-Time), Tab: Fiber Group Statistics
EMS Parameter Name RT / Hist Gauge /
Counter
Parameter Description
Section ESs
RT
Gauge The counter associated with the number of Errored
Seconds encountered by a SONET/SDH Section in the
current 15 minute interval.
Mib name: sonetSectionCurrentESs
Section SESs
RT
Gauge The counter associated with the number of Severely
Errored Seconds encountered by a SONET/SDH
Section in the current 15 minute interval.
Mib name: sonetSectionCurrentSESs
Section CVs
RT
Gauge The counter associated with the number of Coding
Violations encountered by a SONET/SDH Section in
the current 15 minute interval.
Mib name: sonetSectionCurrentCVs
Line ESs
RT
Gauge The counter associated with the number of Errored
Seconds encountered by a SONET/SDH Line in the
current 15 minute interval.
Mib name: sonetLineCurrentESs
Line SESs
RT
Gauge The counter associated with the number of Severely
Errored Seconds encountered by a SONET/SDH Line
in the current 15 minute interval.
Mib name: sonetLineCurrentSESs
Line CVs
RT
Gauge The counter associated with the number of Coding
Violations encountered by a SONET/SDH Line in the
current 15 minute interval.
Mib name: sonetLineCurrentCVs
Line UASs
RT
Gauge The counter associated with the number of Unavailable
Seconds encountered by a SONET/SDH Line in the
current 15 minute interval.
Mib name: sonetLineCurrentUASs
Path ESs
RT
Gauge The counter associated with the number of Errored
Seconds encountered by a SONET/SDH Path in the
current 15 minute interval.
Mib name: sonetPathCurrentESs
Path SESs
RT
Gauge The counter associated with the number of Severely
Errored Seconds encountered by a SONET/SDH Path
in the current 15 minute interval.
Mib name: sonetPathCurrentSESs