2. Physical Description
2.6.1
LEDs
The 8410 blade provides LEDs for indicating the status of various interfaces, as described
in the tables below.
Table
2-12: Blade Status LEDs Description
Label
Color
Status
Description
FAIL
Red
On
Blade failure (fatal error).
-
Off Normal
operation.
ACT
Green
On Active
blade.
Note:
Applicable only to Mediant 3000 HA configuration.
Yellow
Blinking
Redundant blade in standby mode.
Note:
Applicable only to Mediant 3000 HA configuration.
-
Off
Standalone blade (i.e., for Simplex configuration).
Table
2-13: Ethernet LEDs Description
Label
Color
Status
Description
ETH
(1A, 1B,
2A, 2B)
Green
On
10/100BaseT Ethernet link is established. For the status of the
Ethernet ports on the PEM module, refer to ''Power Supply'' on
page
A
LEDs: status of the Ethernet ports located on the lower PEM
module.
B
LEDs: status of the Ethernet ports located on the upper
PEM module.
1A
and
1B
: status of the Control network interface.
2A
and
2B
: status of the OAMP network interface.
Blinking
Data is being transmitted or received.
-
Off
No Ethernet link.
GBE
(1, 2)
Green
On
Gigabit Ethernet link is established. This LED indicates Media
network traffic. For the status of the Ethernet ports on RTM-8410,
refer to ''RTM-8410 Rear Transition Module'' on page
Blinking
Data is being transmitted or received.
-
Off
No Gigabit Ethernet link.
Table
2-14: PSTN E1/T1/J1 LEDs Description
Label
Color
Status
Description
E1 / T1
(1 - 8)
Green
On
E1/T1 is synchronized.
Red
On
Traffic loss due to one of the following signals:
LOS (Loss of Signal)
LFA (Loss of Frame Alignment)
Содержание IPmedia 3000
Страница 1: ...Document LTRT 94704 July 20009 Installation Manual Version 5 8...
Страница 2: ......
Страница 8: ...Installation Manual 8 Document LTRT 94704 Mediant 3000 IPmedia 3000 Reader s Notes...
Страница 12: ...Installation Manual 12 Document LTRT 94704 Mediant 3000 IPmedia 3000 Reader s Notes...
Страница 90: ...Installation Manual Version 5 8 www audiocodes com...