MCD-102-CH (-x), MCD-102-RU (-x)
Audio International, Inc. MCD-103-CH (-x), MCD-102-CP (-x), & MCD-104-01-x
Installation Manual
Document #540031, Rev. B, 4/2000
Page 7 of 18
3.3
Cautions and Warnings
3.3.1 It is important to do a pin-to-pin power and ground check on all
connectors. Ensure that power and ground are applied only where
specified. Damage to the unit may result if power or ground is
applied to the wrong points.
3.3.2 DO NOT connect or disconnect the unit while power is applied.
3.3.3 DO NOT remove any factory-installed screws. Damage to the units
may result and void any warranties.
3.3.4 DO NOT touch the liquid crystal fluid if the LCD case is damaged or
broken. It may be dangerous and cause serious harm. If your
body or clothing come in contact with the fluid, wash immediately
with soap and water.
3.3.4 ESD (Electro Static Discharge) guidelines shall be followed.
3.4
Wiring
Requirements
3.4.1 Introduction
The installing agency shall supply and fabricate all external cables
and mating connectors. The length and routing of external cables
must be carefully studied and planned before attempting installation
of the equipment. Allow adequate space for installation of cable
and connectors. Avoid sharp bends and placing cables near
aircraft control cables. Maintain a minimum clearance of three (3)
inches from any control cable. If wiring is run parallel to
combustible fluid or oxygen lines, maintain a separation of six (6)
inches between the lines.
3.4.2 Power
Wires
All power and ground wires shall be 22 AWG (minimum). Power
ground wires shall be grounded within twelve (12) inches of the
unit. All wires shall be in accordance with MIL-W-22759 or
equivalent. Protect power wires with circuit breakers or fuses
located close to the electrical power source bus.
3.4.3 Audio
Lines
All audio lines are 24 AWG (minimum) twisted shielded pair with
the cable shields properly grounded. Twisted, shielded cable shall