3.3.4 A one (1) inch air space, MINIMUM, is required on top of the unit
for internal cooling fan air circulation.
3.3.5
DO NOT
install near heat sources such as direct sunlight, warm air
exhausts, or heaters.
3.3.6
ESD
(Electro Static Discharge) guidelines shall be followed.
3.4
Wiring
Requirements
3.4.1 Introduction
The installing agency shall supply and fabricate all external cables
and mating connectors. The length and routing of external cables
should be carefully studied and planned before attempting
installation of the equipment. Allow adequate space for installation
of cable and connectors. Avoid sharp bends and placing cables
near aircraft control cables. Maintain a MINIMUM clearance of
three (3) inches from any control cable. If wiring is run parallel to
combustible fluid or oxygen lines, maintain a separation of six (6)
inches between the lines.
Ethernet specifications limit the length of cable between hubs and
other network devices to 100 meters for a total of 200 meters.