background image

IP R

eset

Ready

System

Ready

Not

Output

Line

PoE

Activity

RXD

TXD

GND

5-70 V

AC

Ethernet

PoE+ 802.3at

I/O

WPA-50x

I/O

M

ut

e S

ense I

nput

Public A

ddr

ess      

Ch.A+ Spk O

ut

Ch.A

- Spk O

ut

Ch.B+ Spk O

ut

Ch.B

- Spk O

ut

RS232

Assembled in USA

Rev 7/3/19

Model MS-300

1

PoE+ Network 

Connection

       WPA-50x and I/O Connections

Line 

Output

Stereo 

TRS

Network Status

 and Reset

Amplifier/Speaker 

Connections

Refer to Page #2

Public Address 

Mute/Sense 

Connect

Refer to Page #2          

Connector for: 

WPA-501, WPA-502, 

WPA-504, WPA-505

RS-232

www.AudioEnhancement.com • 800.383.9362

MS-300 Network Interface

Quick Start Manual

I/O In #1

NC   

NC

+24 V

dc

Gnd I/O In #2 I/O Out #1 I/O Out #2

Input/Output

Please Note: Athough there are four I/O connections

there are only two usable I/O ports. Each of the two

I/O ports can be configured, via software, to be either

an Input or an Output. Each I/O port has two connection

pins. One pin is optimized to work as an Input and the 

other pin is optimized to work as an Output. 

Example One:  I/O #1 has been assigned as an Input.

 

You would connect to I/O In #1 and Gnd.

 

Nothing would be connected to I/O Out #1

Example Two: I/O #2 has been assigned as an Output.

 

You would connect to I/O Out #2 and Gnd.

 

Nothing would be connected to I/O In #2

I/O Ports are shared between the WPA-50x connector and

the Input/Output connector. When a WPA-50x is in use, either

one of both of the I/O pins are not available for use.    

I/O I

n #1 (

Call)

Gnd

+ M

ic

+24 V

dc

Gnd I/O I

n #2 (Emer

genc

y)

- M

ic

Gnd

WPA-50x

Отзывы: