background image

Volcano 

1500 RGBW

Please read the manual before using the product

USER´S

MANUAL

7

Volcano 

1500

RGBW

 

9. LED Spe xxx

Adjust the LED speed/strobe/fade of the LED program mode

10. Temper Max:xxx

Adjust the maximum heating temperature of the heating element, adjustable between 285° - 330°C.

11. LED Sync Set Yes/No

Adjust the LED mode. Yes=LEDs work together with the smoke output, NO=LEDs are always on.

TIMER CONTROL

Press the Timer key to activate the timer function. The display shows the adjusted interval and the device 

counts the seconds down to "0". After that, the fog emission is triggered at the volume adjusted under "Volume 

Out". The duration depends on the settings adjusted under "Duration Set". If you wish to deactivate the timer 

function, press the Timer key once more.

Manual control (locked)

Press the Lock button for immediate triggering of the fog emission at the volume adjusted under "Man Volume". 

Press the lock button more in order to stop the fog emission.

Manual control (100% output)

Press the Manual key for immediate triggering of the fog emission at 100 % volume. Let the Manual key loose in 

order to stop the fog emission.

DMX-512 CONNECTION

DMX Control

Connect the machine directly to a DMX controller or a DMX loop with multiple DMX effects. The machine uses 

a 3-pin XLR

connector for DMX connection.

Address Setup:

Press the MODE button a number of times until Add appears on the display, with the UP / DOWN buttons the 

start address may be set. The start address is defined as a first channel to which the machine will respond to. 

Check that there are no overlapping channels used!

OPERATION  

                                                                                                            

•Place the unit on a flat, stable surface which must not be tilted more than 10°

•Fill the tank up to the marking with a good quality smoke fluid.

•Switch the unit on via the On/Off switch on the rear side.

•Switch the unit off after use and unplug it from the mains if it will not be used for a long period of time.

•Rinse the unit regularly with clean water.

REPLACING THE FUSE   

                                                                                          

If the fuse is defective, replace the fuse with a fuse of the same type and value. Before replacing the fuse, 

unplug mains lead.

Procedure:

If you are using a standard DMX controller, you can connect the DMX-output of the controller 

directly to the DMX- input of the first unit in a DMX-chain. Always connect the output of one unit 

with the input of the next unit until all units are connected.

If you use a controller with 5 pin DMX connection you will need to use a 5-pin to 3-pin adapter.

At the last fixture, the DMX cable has to be terminated. Solder a 120 Ohm resistor between 

signal (-) and signal (+)

into a 3-pin XLR connector and plug this into the DMX output of the last fixture in the chain.

Step 1: Open the fuse holder on the rear panel with a fitting screwdriver.

Step 2: Remove the old fuse from the fuse holder.

Step 3: Install the new fuse in the fuse holder.

Step 4: Replace the fuse holder in the housing.

Отзывы: