8.3 ALARMS
The control panel has some systems that control: the ignition, pellet, working power, room temperature, fume
temperature, the proper working of the fan, the proper outlet of pellet combustion gases, etc.
The alarms are used by the control panel to inform us that there is something that blocks the normal working of the
stove:
ALARM
CODE
DESCRIPTION
POSSIBLE CAUSE
SOLUTION
Er01
Activation of the
security thermostat
Security Klixon and/or cable
are
damaged
The temperature in the hopper has
increased a lot
Call the Technical Assistance Service.
Er02
Activation of the safety
air pressure switch
The chimney is very dirty or blocked.
Check and clean the chimney.
Chimney has a lot of pressure loss:
excessive length, excessive horizontal
section, insufficient diameter, incorrect
finish or with net, too much bends, etc.
Check and correct the installation.
Setback of the fumes caused by air
action.
Check the position of the flue duct and
make sure the cowl is suitable.
The last case may be a problem of the air
pressure switch or of its connection with
the control panel.
If you have checked and corrected
every previous step, and the alarm
keeps appearing, call the Technical
Assistance Service.
Er03
Shut down for a low
fumes temperature
There is little pellet in the hopper
A “cave” in the hopper has been
produced and the pellet do not arrive to
the load auger
The load auger has been blocked
or/and the load motor does not spin
Reset the error.
Make sure that the pellet arrives to the
auger (undo the “cave”), put pellet in
the hopper if necessary, and fill up the
auger (see chapter 6.1.3).
If after several attempts of filling up
the auger, it does not fall pellet into the
burner, call the Technical Assistance
Service.
Er05
Shut down for a high
fumes temperature
There is a high temperature in the room
Check the selected room temperature
and that the room thermostat is placed
in a proper place in order to detect the
temperature of the room.
Room fan does not work or it works very
slowly.
In case that this alarm appears often,
or in case you do not get to reset it,
call the Technical Assistance Service.
The fumes probe is missing or has been
damaged. In this case, it would appear
“Hi”
in
the
fumes
temperature
information
“tF”,
and
the
room
thermostat is working to the maximum.
Er07
The electronic board
does not receive any
signal from the speed
controller of the
extractor (combustion
fan)
It may appear sometimes because of
fluctuations in the electric network.
Reset the error and turn it on again.
In case that this alarm appears often,
or in case you do not get to reset it,
call the Technical Assistance Service.
The
fumes fan
and/or any of its
connections are damaged.
Содержание 10 kW
Страница 1: ...PELLET STOVE 6 8 10 KW USER AND INSTALLATION MANUAL ...
Страница 2: ...COD 83119 01EN 12 2015 2 ...
Страница 4: ...COD 83119 01EN 12 2015 4 STOVES 6 8 10 KW 6 kW 8 kW 10 kW ...
Страница 46: ...COD 83119 01EN 12 2015 46 TAS INTERVENTIONS DATE WORKING HOURS INTERVENTION TAS SIGNATURE USER SIGNATURE ...
Страница 47: ...COD 83119 01EN 12 2015 47 ...