RDK-150-DC Supplementary Instruction Manual   

Version 1.2 (May, 2015)

 

 

 WARNING 

 

The default set temperature on RDK-150-DC is 500 ° F. The controller will 
start to heat the coil immediately after it is power up; so please make sure 
the coil is placed in a secure place before power up.  

 

Disconnect the coil from the controller before you change any of the 
parameter that is locked with pass code. Failure to do so may result in 
coil heater damage from overheating.  

 

The coil heater should NOT be heated above 1000 ° F.  Build-in alarm is 
preset to 1000 ° F. 

 

When controller is turned off, the coil will stay at very high temperature for at 
least 20 minutes. The heated coil is very dangerous: it will cause severe 
burn if touched.  

 

1.

 

Introduction 

This is a supplementary manual for the RDK-150-DC hot runner coil heater. 
Only the advanced parameter settings will be covered in this manual. Please 
check the main instruction manual for a quick guide. Advanced parameters are 
divided into groups and can be accessed by entering a special access code.    

 

2.

 

Parameter Setting 

2.1. Temperature setting and Alarm setting (accessed by code 0001)

 

Table 1. Temperature and alarm parameters

 

Symbol

 

Description

 

Range

 

Initial

 

Note

 

SV

 

SV 

Target 

temperature 

Arbitrary value 

within the 

measuring range 

500 

Note 1 

AH1 

AH1 

Alarm 1 on 

temperature 

1000 

Note 2 

AL1 

AL1 

Alarm 1 off 

temperature 

999 

 

AH2 

AH2 

Alarm 2 on 

temperature 

250 

 

AL2 

AL2 

Alarm 2 off 

temperature 

250 

 

END 

END 

Exit 

 

 

 

 

Note 1. Set Temperature. 

There are two ways to set the target temperature. 
a. During the normal operation mode, press Λ or V once to switch the 
display from process value (PV) to set value (SV, or target temperature). 
The display will start to blink. Press Λ or V again to increase or decrease 
the SV. When finished, wait 8 seconds and the settings will take effect 
automatically (the display will stop blinking). 
b. Press SET key once. Use >, Λ and V keys to enter code 0001. Press 
SET key to confirm, then the display would be SV (Su). Press SET key 
again to display the SV setting. Use >, Λ and V keys to enter the new SV 
value and press SET to confirm. Press V key to change the display to 
END. Then, press SET to exit. You can also ignore the steps after 
confirmation of SV. The controller will return to normal operation mode 
automatically if no key is pressed for 1 minute. The flow chart below 
shows how to set the SV and alarms in details. 

 

Operation Mode

XXXX

0001

Enter Code

Parameter Display

Buzzer On Temp

sv

    

0200

0250

    

0250

Target Temp Selection

0249

ah1

al1

ah2

end

Buzzer Off Temp

Buzzer On Temp

SET

SET

SET

SET

SET

SET

SET

SET

    

0250

al2

SET

SET

SET

SET

SET

Buzzer Off Temp

 

Figure 1. Flow chart for how to set target temperature and alarm. 

 

Note 2. Set alarm 

The controller offers two alarms that can be set to turn on the buzzer at 
specific temperatures. The first alarm is controlled by parameters AH1 
and AL1. The initial setting will turn on the buzzer at 1000°F and off 
when temperature drops below 999°F. The second alarm is controlled by 
parameters AH2 and AL2. The second alarm is initially deactivated.   
 
AH1 and AH2 are the temperatures to turn buzzer on; AL1 and AL2 are 
the temperatures to turn buzzer off. When AH1(2) >AL1(2), the alarm is 
set for absolute high alarm as shown in Figure 2 below. When AH1(2) 
<AL1(2), the alarm is set for absolute low alarm as shown in Figure 3 
below. When AH1(2)=AL1(2), the alarm is deactivated. 
 
Example, if AH1=250, AL1=249, when the temperature goes up to 
250°F, the buzzer will be on; when the temperature drops down to 
249°F, the buzzer will be off.  
 
User can press the shift key (>) to temporarily mute the buzzer sound. 
The alarm will buzz again if the alarm set temperature is reached again. 
To permanently deactivate the alarm, set AH1=AL1 or AH2=AL2. Please 
see flow chart in Figure 1 on how to set the value.

 

 

Buzzer on

Buzzer on

PV

PV

 

Figure 2. Absolute high alarm                                 Figure 3. Absolute low alarm

 

 

 