1. Quick list of key functions:

 

1). Key A (or Key RUN) is used to start or resume the program in step mashing mode or event timer in boiling mode. Press Key A momentarily to start the new 
program/timer or resume the current held program/timer. 
 
2). Key B (or Key HOLD/STOP) is used to hold or stop the program in step mashing mode or event timer in boiling mode. Press Key B momentarily to hold the current 
program/timer. Press and hold Key B for 5 seconds to stop the current program/timer.   
 
3). Rotary Knob. You can rotate this knob clockwise or counter-clockwise to increase/decrease the value. This knob is also needed to enter the setting menus. Push 
down this knob momentarily to enter the first layer of menu, which you can reset the timer, or change between mashing and boiling modes. Push down and hold this 
knob for 5s to enter second layer of menu, which you can adjust step mashing temperature & time profile, timer events in boiling mode and also other advanced alarm 
& system settings. For details, please check its main manual. 
 

2. FAQs:

 

1) Q: What is the difference bet

ween “

HOLD

” and “

STOP

”?

 

A: “

HOLD

” will maintain your target at previous set temperature or set percentage. For example, assuming the set temperature is 150F before “

HOLD

” action, after 

HOLD

”, th

e controller will maintain at 150F as well. Or assuming the o

utput percentage is 90% before “

HOLD

 action, after 

HOLD

”, the controller will maintain at 90% 

output as well. To resume, you can press Key A momentarily. 
 

STOP

” will stop the whole program and disable the output.  

There will be no output then, no matter what status it 

is before “

STOP

” action. 

After 

STOP

, you cannot 

resume the program/timer, but only restart the program/timer from the beginning. To restart, you can press Key A momentarily. 
 

2) Q: What is the diff

erence between “

END

” and “

STOP

”?

 

A: “

END

” is triggered by the controller. It means the 

whole step program or timer event is completed. After program/timer ends, the power output can be configured 

either to continue heating, or shut off. It is controlled by the parameter EO in step mashing mode, or bEO in boiling mode. If you want to run another step mashing 
program, you need to 1) simply reboot the controller, or 2) 

change “

END

” status to “

STOP

” status

 by the knob at first, then push Key A to restart: Push down the knob 

momentarily and change “rst” to “y”, then push down the knob again to confirm. 

 

 

STOP

” is triggered by key function (by holding

 

key B), or by programmed step (you can program specific step to “

STOP

” in step mashing mode). When program/timer 

is stopped, output will be disabled. 

Once “

STOP

”, you can only restart the program from the first step (press Key A), and you cannot go to the

 next step after that 

STOP

” step.

 

 

3. Program Examples: 
1) S

tep mashing program (under menu “PROG”

, section 6.2 in page 5 of its main manual):  

 

Parameter

 

Initial Setting

 

Parameter

 

Initial Setting

 

C-1 

122 

t-1 

00:30 

C-2 

140 

t-2 

00:20 

C-3 

154 

t-3 

00:40 

C-4 

168 

t-4 

00:15 

C-5 

50 

t-5 

00:00 

C-6 

50 

t-6 

00:00 

Table 1. Step mashing program example.  

 
Each step has two parameters. C-X is the set temperature for that step, and t-X is the time duration for that step, where X is the step number. This program will control 
at the temperature of 122F for 30 minutes at first. Then raise the temperature to 140F and hold there for 20 minutes. Then raise the temperature to 154F and hold there 
for 40 minutes. Finally raise the temperature to 168F and hold there for 15 minutes. Then end the program (timer is set to 0 for step 5 and 6). 
 

2) Timer event settings for boiling mode (under menu “BOIL”, section 

6.3 in page 6 of manual) 

 
nE = 3, Bot1 = 1:00, Bot2 = 00:10, Bot3 = 00:01, Bot4 ~ 9 are hidden.  
 
This example is for: first ingredient (bot1) needs total 60 minutes of boil, the second ingredient (bot2) needs 10 minutes of boil and third ingredient (bot3) needs 1 
minutes of boil. Assuming the timer will start at 0 minute (add first ingredient here). 50th minute from the beginning, controller will beep and let you add second ingredient. 
59th minute from the beginning, controller will beep again to remind you it is the time to add the third ingredient. 
 