Auber Instruments DSPR300 Скачать руководство пользователя страница 1

  AUBER INSTRUMENTS

    

 

 

     

 

 

 

             

WWW.AUBERINS.COM  

 

2021.05                                                                                                                                                                                                          P1/9

 

                 

                                                                                                                          

EZboil, Power Regulator for Boiling Process Automation DSPR300 

Version 1.3 (May, 2021) 

 

 

Caution

  

 

This  controller  is  intended  to  control  equipment  under  normal  operating 
conditions.  Failure  or  malfunction  of  the  controller  may  lead  to  abnormal 
operating  conditions,  which  result  in  personal  injury  or  damage  to  the 
equipment  or  other  property.  Devices  (limit  or  safety  controls)  or  systems 
(alarm  or  supervisory)  intended  to  warn  of  or  protect  against  failure  or 
malfunction of the controller must be incorporated into and maintained as part 
of the control system. 

 

Installing the rubber gasket supplied will protect the controller front panel from 
dust and water splash (IP54 rating). Additional protection is needed  for higher 
IP rating. 

 

This  controller  carries  a  90-day  warranty.  This  warranty  is  limited  to  the 
controller only. 

 

1.

 

Specifications 

Input type 

RTD (Resistance Temperature Detector): Pt100 

Accuracy 

±  0.2% full scale 

Temperature 
range 

-328° F ~ +932° F, -200° C ~ +500° C 

Response time 

 0.5s 

Display 
resolution 

1° C or ° F 

Control mode 

Mashing, Boiling 

Alarm function 

Process/derivation high/low alarm, Acceleration and 
timer alarm, Latching/pulse action 

Alarm output 

Relay contact: 3A for resistive load. 1A for inductive 
load 

Power supply 

85~260 VAC/50~60 Hz 

Power 
consumption 

 5 Watt 

Working Ambient 
temperature 

0~50ºC, 32~122ºF 

Dimension 

48 x 48 x 100 mm (W x H x D, from the front panel to 
the back) 

Mounting cutout 

45 x 45 mm 

 

2.

 

Front Panel 

8

5

4

1

2

3

7

6

9

 

Figure 1. The front panel of DSPR300.  

1). Top display.

 This display indicates the temperature sensor read out value. 

When timer is activated, it will show time and temperature alternately. 

2). Bottom display.

 In boiling mode, this display will show the percentage of 

power being sent to the external SSR after the initial heat up phase. In mashing 
control mode, this display will show the set temperature. 

3). Temperature setting adjusting indicator.

 This is the small dot at the lower 

right corner. In mashing mode, when temperature set point is adjusted, it will 
start  to  flash.  It  reminds  you  that  you  need  to  press  the  knob  to  confirm  the 
change. Otherwise, the temperature setting will return back in 2 seconds after 
you stop the adjustment.  

4). AL1 indicator

. This red LED indicates the status of Relay 1 (AL1). When it 

is on, the relay is closed; when it is off, the relay is open. 

5). AL2 indicator

. This red LED indicates the status of Relay 2 (AL2). When it 

is on, the relay is closed; when it is off, the relay is open. 

6).  Mashing  mode  indicator  (MASH). 

This  yellow  LED  light  indicates  the 

operation mode of the controller. When it is on, controller is in mashing mode; 
when it is off, controller is in boiling mode.  

7). Output indicator (OUT).

 This green LED light is synchronized with output. It 

shows how much power the regulator is sending out (as a 12VDC control signal 
pulse through terminal 6 and 7). When it is on solid, the output is 100% on. When 
it  is  off,  there  should  be  no  output.  When  it  is  flashing,  the  frequency  of  the 
flashing is an indication of high or low power output. Higher frequency means 
higher power output.  

8). Rotary switch (knob).

 Turn it clockwise to increase the output power (or 

selected parameter value); turn it counter-clockwise to reduce the output power 
(or selected parameter value). Press it briefly to reset the timer (if enabled) and 
to switch between mashing and boiling mode. Press and hold it for 5 seconds to 
enter parameter settings menu. Please see section 6 for details. 

9). Function key A & B.

 

There are two Function Keys named “A” and “B” can 

be used to reset/cancel relays. 

Key “A” is for Relay 1, Key “B” 

is for Relay 2. 

Please check note 20. 
 

3.

 

Wiring Terminals 

The pin assignment of the back terminals of DSPR300 is shown in Figure 2.  

1
2
3

13 14 6

7
8
9

10

4
5

AL1

AL2

AC

85~260V

SSR

+

-

RTD

R

R

W

 

Figure 2. Terminal assignments of DSPR300.  

 

3.1 Sensor connection 

DSPR300 only accepts Pt100 RTD temperature sensor. For a three-wire RTD 
with  standard  DIN  color  code,  the  two  red  wires  should  be  connected  to  the 
terminals 3 and 4. The white wire should be connected to terminal 5. For a two-
wire RTD, the wires should be connected to terminals 4 and 5. Jump  a wire 
between terminals 3 and 4.  
 

3.2 Power to the controller 

The power cables should be connected to terminals 9 and 10. Polarity does not 
matter. It can be powered by 85-260 VAC power source. Neither a transformer 
nor jumper is needed to wire it up. For the consistent with the wiring example 
described later, we suggest you connect the hot wire to terminal 10 and neutral 
to 9. 
 
 

Instruction Manual

 

 

Содержание DSPR300

Страница 1: ...ill return back in 2 seconds after you stop the adjustment 4 AL1 indicator This red LED indicates the status of Relay 1 AL1 When it is on the relay is closed when it is off the relay is open 5 AL2 ind...

Страница 2: ...splay mode 3 Parameter settings Press down and hold the knob for 5 seconds to enter the display mode 3 Please check section 6 for details 5 Operation 5 1 Operation mode selection This controller offer...

Страница 3: ...zero see section 6 3 for details For how to set up the boiling mode please read section 6 3 6 Control Parameters Parameters are divided into four groups figure 5 MASH for mashing control BOIL for boil...

Страница 4: ...ant End Figure 7 Flow chart of setting mashing parameters Note 6 Timer Function t tSP EO This timer function allows the controller to show the mashing time It makes a beeping sound when timed out and...

Страница 5: ...termined by the bOUT When temperature rise to the bAST the output will automatically reduce to a lower level to prevent a messy boiling over The boiling over is caused by several factors including the...

Страница 6: ...menu for system settings there are five pairs of parameters for configuring relays Table 4 Alarm Parameters in System Configuration System Configuration Alarm parameters part 1 Display Code Descriptio...

Страница 7: ...Alarm Suppression is only supposed to work when 1 controller is just powered up and 2 the condition that deactivates the Relay Silence is not met yet This feature is available in all relay modes howev...

Страница 8: ...Lgc1 RL_C LAt1 N AH1 200 AL1 100 and HY 3 temperature unit is F For the high limit alarm when the process temperature is greater and equal to 200 F the relay will pull in and when process temperature...

Страница 9: ...Power supply for two buzzers is 120V AC AL1 buzzer is for temperature alarm AL2 buzzer is for timer alarm 10 Common sensor errors This regulator will display error message or incorrect temperature re...

Страница 10: ...er Figure 5 Original AC sine wave is overlaid with SSVR output wave form The blue colored area shows the power output that has been blocked 2 Time proportional firing A fixed cycle time needs to be de...

Страница 11: ...gnal drop to zero the AC power is blocked 3 Burst firing This method is similar to time proportional firing section 2 But in contrast to the time proportional mode where the SSR is fired once for each...

Страница 12: ...eform overlaid The DSPR detects the frequency and phase of the AC power line so that the pulse width and firing time is synchronized with AC cycle Auber Instruments 5755 North Point Parkway Suite 99 A...