background image

The CT240 telephone controller is designed to remotely control your
home’s thermostat. It is possible to command a temperature
decrease (Unoccupied) during a prolonged absence or a temperature
increase (Comfort) before you return home.

Depending on your thermostat’s operating characteristics, it either
connects to the Aube output (for most Aube models) or to the auxil-
iary output. 

When the auxiliary output is not used to control a thermostat, it can
be used to simultaneously control a load such as a water heater,
lighting, etc. 

)LJXUH  

ЛнкЯрЮпϫ Ксансдатϫ

Any device connected to a telephone line must conform to the coun-
try's standards. The CT240 telephone controller meets: 

• FCC68 standards for installation on the North American network.

• FDTBR21 standards for installation on the European network.

2.1 Included Parts

• One CT240 telephone controller

• One power transformer 120 V (North America) or 250 V (Europe)

• One 5 m (16 foot) telephone cable

NOTE:

If you are using an answering machine, position the answer-

ing machine switch to ON before installing the CT240. 
Make sure that your answering machine answers after a minimum of
4 rings.

)LJXUH 

Ќйотандйвϫ И ЬЮгд йаϫ ОтдпЮг

)LJXUH 

Пфлд ЮЬзϫ Д й опЬзз Ьпдкй

n

Mount the CT240 near a telephone outlet.

NOTE:

If you plan to connect a load having more that 30 volts on the

auxiliary output, the CT240 must be installed inside a certified electri-
cal box.

o

OPTIONAL. Connect your phone (or answering machine) to the 
PHONE connector of the CT240.

p

Connect one end of the telephone cable to the LINE connector of 
the CT240 and the other end to the telephone outlet in your 
home.

q

Connect the thermostat and load. Both outputs work simulta-
neously. 

NOTE:

Refer to your thermostat’s electrical specifications (telephone

interface) for the connection requirements.

If your thermostat requires a 12 VDC signal to switch to Vaca-
tion setpoint, use the ABC output (FIGURE 4):
A and C terminals: 
• 0 VDC in Comfort mode 
• 12 VDC in Vacation mode

NOTE:

50 mA max. for parallel connection of Aube thermostats.

If your thermostat requires a dry contact to switch to the Vaca-
tion setpoint, use the 123 output (FIGURE 5):
• Load = terminals 2 and 3 (NC) (open = Vacation)
• Thermostat = terminals 1 and 2 (NO) (closed = Vacation)

r

When all connections have been made, connect the power 
transformer to the 9 V outlet of the CT240 and the other end to 
the wall electrical outlet. The power indicator light 

 is ON when 

the circuit is powered. 

)LJXUH 

ϼ Ͻϫ СЏЎϫ Од вй Ьзϫ пкϫ пганикопЬп

)LJXUH 

Џ нфϫ ЮкйпЬЮпϫ пкϫ пганикопЬп

1 . Introduction

1

Power Indicator.

Indicates the CT240 is powered on. To turn 

it off, unplug the power transformer.

2

Communication Indicator.

Indicates the CT240 has 

answered and is awaiting a command.

3

Ring Indicator.

This indicator flashes when the phone rings.

4

Reset.

This button can be used to reset the CT240 to its 

default values. See section 3.3.

5

Manual Output Activation Button.

Can be used to manually 

switch the relay status.

6

Auxiliary Output.

See section 2.

7

12 VDC Output.

See section 2.

2. Installation

CT240 Telephone

Controller

Installation Instructions and User Manual

1/2        400-240-001-A

Отзывы: