CHAPTER 6: REMOTE DEVICE ALERTS
MDU Solutions
®
– UCrypt
®
Monitoring Server - Operation Manual
6-15
6 .21 .1 Refers to
Programs known to be assigned to tuner boards will be missing from the output.
6 .21 .2 Repetition of Alert
Alert is sent only once per occurrence.
6 .21 .3 Customer Symptoms
Missing programs.
6 .21 .4 Urgency
High
6 .21 .5 Cases Where Alert is Likely a Result of:
Outside influence or normal operation
If this alert is accompanied by other alerts, analyze the sum total of the alerts to determine a possible outside cause as there
may be some common problem which cannot be predicted here. This alert would not normally be expected. The UCrypt may
be installed in a dirty environment whereby the slots of the motherboard have become dirty and connections to tuner boards
are failing.
An Internal Issue
Dirty motherboard PCIe slot, bad PCIe slot, f/w issue, internal overheating.
6 .21 .6 Probable Causes
1. Dirty unit, defective PCIe slot contacts.
2. Failing tuner board.
6 .21 .7 Next Steps
1. Power Cycle unit.
2. Ensure fans are all functional.
3. Ensure ambient air temperature is within specification.