CRAFT LINE INTERFACE (CLI)
TranScend Chassis – Operation Manual
5-13
Attenuation:
Displays the attenuation setting in dB.
Example #1: In this example, the module in slot 1 reports its attenuation setting as 0 dB.
Transcend [slot-1] >attenuation
+0.0
dB
OpticalPowerAlarm:
Displays the alarm status of optical input power.
Example #1: In this example, the module in slot 1 reports the alarm status of optical input power as
“MajorLoLo” (e.g. Major alarm with power reading below the low low threshold).
Transcend [slot-1] > OpticalPowerAlarm
MajorLoLo
ModuleTempAlarm:
Displays the alarm status of module temperature.
Example #1: In this example, the module in slot 1 reports the alarm status of module temperature as Normal.
Transcend [slot-1] >ModuleTempalarm
Normal
Composite Commands:
The composite commands provide a quick way to poll system information and status via one
single command. The followings are example of composite command output for Forward Receiver.
Info:
System
SwVer:
1.6-2.f
HwVer:
3-2
ModelName:
TSD_SwCntlr
SerialNum:
01420070901234
Slot 1 (FwdRcvr)
SwVer:
2.f-2.f
HwVer:
1-2
ModelName:
TSD-FWRX
SerialNum:
01420070901234
Status:
Transcend[slot-1]
>status
Slot 1 (FwdRcvr)
ModuleTemp (deg C):
Содержание TranScend
Страница 1: ...OPERATION MANUAL TranScend Chassis www atxnetworks com www atxnetworks com TranScend ...
Страница 6: ...SCOPE 1 2 TranScend Chassis Operation Manual This page intentionally left blank CHAPTER 1 ...
Страница 12: ...LED DISPLAY 2 6 TranScend Chassis Operation Manual This page intentionally left blank CHAPTER 2 ...
Страница 44: ...FRONT PANEL LCD DISPLAY 4 30 TranScend Chassis Operation Manual CHAPTER 4 This page intentionally left blank ...
Страница 70: ...CRAFT LINE INTERFACE CLI 5 26 TranScend Chassis Operation Manual CHAPTER 5 This page intentionally left blank ...
Страница 76: ...GRAPHICAL USER INTERFACE 6 6 TranScend Chassis Operation Manual CHAPTER 6 This page intentionally left blank ...