ATX Q-Series Power BAQ-UP Скачать руководство пользователя страница 5

           Q-Series

®

 Power – BAQ-UP™ (QRED) Redundancy Switch with Backup Amplifier – Installation & Operation Manual  

1-1

CHAPTER 1: DESCRIPTION OF INTERFACES

DESCRIPTION OF INTERFACES

1. 

Description of Interfaces

The BAQ-UP™ system (the system) has three compartments: the amplifier compartment, the power supply compartment, 

and the RF switch compartment.

Power Supply Compartment:

 

(Located in the center portion of the chassis)

a) 

Rear:

  24 VAC Input   

 

 

24 VDC Input

b) 

Front:

  Green LED: 24V power on

Description:

 Both the 24 VAC and the 24 VDC can be connected at the same time to their designated terminal strips. A diode 

“OR circuit” is located internally to select the source with the highest voltage. This allows you to provide redundant power to 

this device by simultaneously connecting the 110 VAC / 24 VAC supplied transformer to the AC terminals when you also have 

connected a 24 VDC source to the DC terminals. The green LED on the front indicates proper power supply operation.

RF Amplifier Compartment:

 (Right side of chassis facing back)

a) 

Rear: 

Input (located immediately to the right of the AC/DC terminal block)

 

 

Output (located at the extreme right of the chassis)

b) 

Front:

 (with cover removed):

 

Input Test Point

 

Output Test Point

 

Gain Control

 

Slope Control

 

Input Pad (used to optimize the input to the amplifier)

Description:

 This is referred to as the secondary amplifier because your existing amplifier is referred to as the primary 

amplifier. This internal amplifier has a low-noise front-end and is comparable in signal quality to any primary amplifier.

RF Switch Compartment:

 (Left side of chassis facing back)

a) 

Rear: 

Main Signal Input (located immediately left of AC/DC terminal block)

 

 

Output to Primary Amp

 

 

Output to Secondary Amp

 

 

Input from Primary Amp

 

 

Input from Secondary Amp

 

 

Main Output (on extreme left side facing back of chassis)

Description:

 If you are connecting this amp/switch as a redundant amp for your existing amplifier, then move the input 

from your existing amplifier to the main signal input connector for this device. Connect a cable from the “Out to Primary” 

connector to the input of your existing amplifier. Move the output of your existing amplifier to the “In from Primary” connector. 

Connect a cable from “Out to Secondary” to the secondary amplifier input located immediately to the right of the 24 VDC / 24 

VAC terminal connectors. Connect another cable from “In from Secondary” to the secondary amplifier output located to the 

extreme right of the chassis as you are facing the rear of the chassis.

BAQ-UP™ Front View

Содержание Q-Series Power BAQ-UP

Страница 1: ...BAQ UP QRED Redundancy Switch with Backup Amplifier Q SERIES Power Installation Operation Manual ...

Страница 2: ... by one or more U S or foreign patents Other non ATX product and company names in this manual are the property of their respective companies Although every effort has been taken to ensure the accuracy of this document it may be necessary without notice to make amendments or correct omissions Specifications subject to change without notice ...

Страница 3: ...nstallation Operation Manual i TABLE OF CONTENTS Page 1 DESCRIPTION OF INTERFACES 1 1 2 DESCRIPTION OF OPERATION 2 1 2 1 Functional Schematic 2 2 3 SET UP PROCEDURE 3 1 4 SPECIFICATIONS 4 1 5 SERVICE SUPPORT 5 1 5 1 Contact ATX Networks 5 1 5 2 Warranty Information 5 1 ...

Страница 4: ...ii Q Series Power BAQ UP QRED Redundancy Switch with Backup Amplifier Installation Operation Manual This page left intentionally blank ...

Страница 5: ...over removed Input Test Point Output Test Point Gain Control Slope Control Input Pad used to optimize the input to the amplifier Description This is referred to as the secondary amplifier because your existing amplifier is referred to as the primary amplifier This internal amplifier has a low noise front end and is comparable in signal quality to any primary amplifier RF Switch Compartment Left si...

Страница 6: ...ED 5V power on Yellow LED warning On using reference levels stored in EEPROM Flashing 1 sec Needs to set reference levels Flashing 3 sec Switched to the secondary amplifier by the remote control switch Red LED alarm On Primary amp failure Flashing 1 sec Secondary amp failure Flashing 3 sec Input signal low primary amp and secondary amp failure RF Detectors Primary Amp RF Level Detector DC level pr...

Страница 7: ...ickly and set the alarms The system needs to be reset at this point to get back to normal operation after correcting the input levels If the system is running on the primary amp and the secondary amp level is down 3 dB or more the system considers the secondary amp failed and will set Alarm 2 and set the red LED flashing slowly The system should be reset at this point to get back to normal operati...

Страница 8: ...ed to switch to the secondary amplifier when the cumulative RF output of the primary amplifier falls below a programmed level usually a 3 dB drop This output is measured within a frequency range from 120 220 MHz The microprocessor controlled switch can be programmed to switch within the end users specifications for timing and RF levels Once a switch is made to the secondary amplifier the signal pa...

Страница 9: ...mpartment 10 Push the Set Ref Levels switch 11 Connect the and contact of the remote switch with a jumper to force the microcontroller switch to the secondary amplifier 12 Adjust the gain and slope control in the amplifier compartment to get desired signal level 13 Remove the jumper from the remote switch 14 Remove the signal strength meter from the Output of the RF switch compartment 15 Connect t...

Страница 10: ...3 2 Q Series Power BAQ UP QRED Redundancy Switch with Backup Amplifier Installation Operation Manual CHAPTER 3 SET UP PROCEDURE This page left intentionally blank ...

Страница 11: ...Q Series Power BAQ UP QRED Redundancy Switch with Backup Amplifier Installation Operation Manual 4 1 CHAPTER 4 SPECIFICATIONS SPECIFICATIONS 4 Specifications ...

Страница 12: ...4 2 Q Series Power BAQ UP QRED Redundancy Switch with Backup Amplifier Installation Operation Manual CHAPTER 4 SPECIFICATIONS This page left intentionally blank ...

Страница 13: ... Free 800 565 7488 USA Canada only Press 3 for Technical Support Then press 1 for Digital Video Products DVIS DigiVu UCrypt etc OR press 2 for All Other Products Email digitalvideosupport atxnetworks com for Digital Video Products Email jleskovar atxnetworks com for All Other Products CUSTOMER SERVICE ATX Networks 1 501 Clements Road West Ajax ON L1S 7H4 Canada Tel 905 428 6068 Toll Free 800 565 7...

Страница 14: ...nted in Canada Rev 07 15 ANW0849 1 501 Clements Road West Ajax ON L1S 7H4 Canada Tel 1 905 428 6068 Toll Free 1 800 565 7488 Fax 1 905 427 1964 Toll Free Fax 1 866 427 1964 www atxnetworks com support atxnetworks com ...

Отзывы: