![ATX MAXNET MNRS Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/atx/maxnet-mnrs/maxnet-mnrs_installation-and-operation-manual_3006233011.webp)
ATX
Confidential & Proprietary
CHAPTER 3: THRESHOLD LEVEL SETTINGS
DEVICE RESET
4. Device Reset
4.1. Redundant Amplifier Configurations
After the MNRS has switched (B ACTIVE LED
on
and the RF bar graph blank), the operator should determine the cause of
the transfer from primary amplifier A to backup amplifier B.
Once the cause has been identified and corrected:
•
Ensure that the wiring is correct
•
Press and release the reset (RESET) push button:
◦
the B ACTIVE LED should turn
off
◦
the RF PWR level bar graph should indicate a level between 40 and 70 dBmV
4.2. RF Detector A/B Switch Configurations
No reset required. Device returns to primary mode when signal source A returns to a power level above the threshold level.
MAXNET
®
– MNRS Redundant RF Detector/Switch Module – Installation & Operation Manual
4-1
CHAPTER 4: DEVICE RESET