STATUS MONITORING FEATURES
4. Status Monitoring Features
4.1. SNMP Parameters
MAXNET
®
II – QMP200 Return RF/IF Amplifier Manual – Installation & Operation Manual
4-1
CHAPTER 4: STATUS MONITORING FEATURES
CHAPTER 3: STATUS MONITORING
Display Name
Description
HMS MIB Variable
Model
ATX model number (note, in empty slots you can enter
passive, dual-passive, or empty to populate the overview
page with passive picture placeholders).
entPhysicalModelName
Description
Description of the module.
entPhysicalDescr
Name
Indicates the slot of the chassis the module is in.
entPhysicalName
Alias
Optional user defined field - added to fifth variable binding
of traps and emails
e.g. set this to “Node 69” for a given Receiver and any
alarms generated by this receiver will have “Node 69”
in the description. Otherwise, it would only contain the
IP address of the chassis, the Model and Name (slot
number).
entPhysicalAlias
Manufacturer
ATX
entPhysicalMfgName
Asset I.D
Optional user settable field (suggestions: enter in a
custom serial number or purchase order # for tracking).
entPhysicalAssetID
Serial No
Module’s serial number.
entPhysicalSerialNum
Hardware Rev
Hardware rev of module.
entPhysicalHardwareRev
Firmware Rev
Firmware rev of module.
entPhysicalFirmwareRev
Temperature [C]
Module’s current heatsink temperature.
heCommonTemperature
Alarm Detection Control
detectionEnabled: normal operation, with active alarms
detectionDisabled: used to temporarily disable alarms/
traps from this module
detectionEnabledandRegenerate: enter detectionEnabled
state while regenerating all alarm table entries
heCommonAlarmDetectionControl
Fan Unit Status
Alarm status of the fan.
heFanUnitAlarm
Display Name
Description
HMS MIB Variable
Voltage In [Volt]
Measured voltage supplied to the module from the
chassis (nominally 24V).
hePsUnitVoltageIN
Current In [mA]
Current taken from the 24V rail by the module.
hePsUnitCurrentIN
Power In [Watts]
P.S. Voltage * P.S. Current
hePsUnitPowerIN
RF Amp Output
Description
Description of the approx gain value of the amp.
heRFAmpOutputDescription
RF Amp Output Level
[dBmV]
Composite RF level at output of amp.
heRFAmpOutputLevel
Table #8: Common Module SNMP Parameters
Table #9: QMP200 SNMP Parameters