ATV QSP-860MPX Скачать руководство пользователя страница 9

 

QSP-860MPX:  Instructions for Basic Operation and Installation

Page 9

A

DVANCED 

F

UNCTION 

M

ENUS

This section describes the use of the advanced functions of the QSP-860MPX.  The following features
allow you to customize the operation of your QSP-860MPX as necessary to complete your installation.

Camera Set Up

This menu determines the display behavior of the camera
labels and allows access to menus for entering/changing
labels, setting up camera record priority, or to disable a
camera in the live display.  Like time and date, both the
VCR and monitor displays can be independently
enabled/disabled.

Selecting:
1.  Toggles the camera labels ON/OFF for the monitor

display.

2.  Toggles the camera labels ON/OFF for the VCR

display.

3.  Enters “Camera Labels” menu to review, enter, or

change camera labels.

4.  Enters the “Camera Recording Priority” menu (CUSTOMPLEXING

 function).

5.  Enters the “Monitor Disable” menu to allow a camera to be turned off in the live display.

Camera Label Changing

This menu is used for adding/changing labels that are
associated with each of the eight cameras.

Selecting:

1 - 8

Selects the camera for editing and exposes the
legend at the right hand side of the screen.  After
pressing a Camera 1-8 button, the display will
appear as shown.

Since we have a limited set of front panel buttons, all of the
buttons except DISPLAY and VCR are used to input
characters. Using the legend, any character can be entered
in the present character location. The VCR button is used to
move to the next location (to the right).

CUSTOMPLEXING

 (Camera Recording Priority)

Selecting:

1 - 8

Toggles the camera between High (Factory
Default), Alarm Only, Low, and Medium
priorities.

The camera priorities affect how frequently a camera’s
image is stored. The factory default is all cameras set to
“High Priority”.  Using the factory defaults, the camera
multiplexing ordering is:

1,2,3,4,5,6,7,8,1,2,3,4,5,6,7,8,1,2,3,4.........

Using the example shown, the multiplexing order is:

1,2,3,5,1,2,4,1,2,3,6,1,2,4,1,2,3,5,1,2,4,1,2,3,6....

The QSP-860MPX priority method gives medium priority
cameras twice as many frames as low priority cameras.  Similarly, high priority cameras get twice as

   Camera Recording Priority

 1: High Priority
 2: High Priority
 3: Medium Priority
 4: Medium Priority
 5: Low Priority
 6: Low Priority
 7: Alarm Only
 8: Alarm Only
 Camera: Select/Change
 DISPLAY: Previous Menu

       Camera Set Up

 1: Labels on Display: On
 2: Labels on VCR:     On
 3: Change Labels...
 4: Recording Priority...
 5: Monitor Disable...

 PIP: Restore Default Settings
 Camera: Select/Change
 DISPLAY: Previous Menu

      

Camera Labels

Characters
 PIP: 0  Space

 1.  

 . . . . . . . . . . . 

     1: ABC1

 2.  2

     2: DEF2

 3.  3

     3: GHI3

 4.  4

     4: JKL4

 5.  5

     5: MNO5

 6.  6

     6: PQR6

 7.  7

     7: STU7

 8.  8

     8: VWX8

 VCR: Move Rt. QUADRANT: YZ9
 DISPLAY: Accept

Содержание QSP-860MPX

Страница 1: ...and installation Printing Revision 11 Version 2 3 For Serial numbers 1808000 and greater 14842 NE 95th Street Redmond Washington 98052 Phone 888 288 7644 425 885 7000 Fax 425 881 7014 Customer Servic...

Страница 2: ...nce Set Up 10 Dwell Adjustment 10 Display Sequencing Format 11 Sequencing Format Screens 11 Alarm Options 12 Alarm Enable 12 Alarm Dwell Adjustment 12 Alarm Activation Type 13 Other Options 13 Securit...

Страница 3: ...ach camera is alternately output to the VCR with the factory default set so that each live camera is given an equal number of frames on the tape Dead or unconnected camera inputs will not be recorded...

Страница 4: ...steps are 1 Connect your cameras monitor and VCR to the QSP 860MPX as shown above Refer to the Back Panel Connections and Video Termination Switches sections on the next page for proper connections an...

Страница 5: ...computer type cable See page 18 for further alarm connection information 1 5 6 9 1 8 9 15 SERIAL PORT ALARM 12 VAC VCR VCR VIDEO 1 5 2 6 3 7 4 8 IN OUT OUT 2 0 AMP DUAL LOOP DUAL LOOP DUAL LOOP DUAL...

Страница 6: ...quish Screen Full Frame and back to Single PIP displays How cameras will appear in these displays is programmable See Display Sequence Set Up on page 11 QUADRANT ZOOM This button rotates the orientati...

Страница 7: ...menu Selecting 1 Edits the hour of the day In 24 hour mode 1 through 24 is accepted as entered In 12 hour mode values above 12 will have 12 subtracted from the entered value 2 Edits the minutes field...

Страница 8: ...R from the displayed list The first two entries are for standard 12 and 24 hour steps which will accommodate most VCRs Standard 12 Hr steps is the factory default PIP Pages the list forward for more s...

Страница 9: ...n Since we have a limited set of front panel buttons all of the buttons except DISPLAY and VCR are used to input characters Using the legend any character can be entered in the present character locat...

Страница 10: ...era s video is shown A Record Only camera s video is still multiplexed Selecting 1 8 Toggles the camera s live display from Display on Monitor to Record Only The default is Display on Monitor In the e...

Страница 11: ...ending numerical order and cameras cannot be repeated For example if the pattern 7 5 2 4 5 5 7 were entered the software will translate this to 2 4 5 7 Display Sequence Set Up 1 Hold Each Image for 3...

Страница 12: ...splay will determine how long a continuous alarm camera will be displayed This can be adjusted so that a continuous alarm will not consume all of the VCR s record time A value of zero factory default...

Страница 13: ...ctivation is defined as follows Contact Closure The alarm pin is connected to a current source either 5V or ground Contact Open The alarm pin is not connected to any current source unconnected pin Log...

Страница 14: ...ence of the Camera Switch Input pulse The default is 2 4 Toggles the VCR Playback Discriminator circuit On Off The playback discriminator should be left On unless you wish to view all recorded frames...

Страница 15: ...he following steps before contacting the factory To program the remote control to work with the QSP 860MPX 1 Ensure that batteries are properly installed in the QSP 860MPX Remote Control 2 Turn on the...

Страница 16: ...icular VCR Satisfactory performance can be obtained by setting up the one or two formats you actually plan to use according to the following basic guidelines What is the Delay Table The delay table is...

Страница 17: ...y table and create a custom delay table select the VCR Set Up menu option 2 from the Main Menu Then select Advanced VCR Options option 4 Select Edit Delay Table option 1 and the menu shown here will a...

Страница 18: ...ven to the limitations introduced by these current limiting resistors The alarm connector on the QSP 860MPX is a DB 15 15 pin connector For ease of installation a breakout adapter is provided with the...

Страница 19: ...impedance If a higher voltage or higher current relay is used an external supply is required Under these conditions the open circuit voltage no alarm on pin 9 must not exceed 30 Vdc and the closed cir...

Страница 20: ...n will cause the QSP 860MPX to freeze current display video BB VCR Button will cause the QSP 860MPX to enter the VCR bypass mode BC n Camera Button n is a number 1 through 8 corresponding to the camer...

Страница 21: ...VT S3100 Sony SVT L200 Sony SVT L400 Sony WatchCorder Toshiba KV5168A Toshiba KV6200A short long Toshiba KV7024 Toshiba KV7168A Toshiba KV7960A short long Toshiba KV8168A Toshiba KV8168AHD Toshiba KV8...

Страница 22: ...Ohms Digital Sampling 512H x 512V x 8 Bits 256 Gray Levels Refresh Rate 30 Fields Per Second EIA 25 Fields Per Second CCIR Electrical Power 12 V AC 2 Amp Safety 110V 60Hz Power Supply UL Listed and C...

Страница 23: ...Year where Year is a two digit representation of the year Conformity is defined as follows 1 No value for the current date will cause any interruption in operation of the product 2 Date based functio...

Отзывы: