ATV QSP-860MPX Скачать руководство пользователя страница 5

 

QSP-860MPX:  Instructions for Basic Operation and Installation

Page 5

4. 

Determine the record speed (record hours format) you will use with your VCR and set up
the QSP-860MPX to work with your VCR using the “VCR Set up” and VCR Selection”
menus (see page 8).

5. 

Exit the QSP-860MPX menus by pressing the DISPLAY button to exit each menu and
finally the menu system.

6. 

If your VCR has internal “on-screen” menus for its set up, use the “VCR Bypass” feature
of the QSP-860MPX (see the VCR button function description on page 6) to view the
VCR’s “on-screen” menus on the display monitor.

7. 

At this point, the basic configuration of your QSP-860MPX is complete.  You may now
proceed to set more advanced functions as required for your installation (alarms, camera
labels, multiplexing options, etc.).  Refer to the “Advanced Function Menus” starting on
page 9 for detailed information for the feature(s) you require.

B

ACK 

P

ANEL 

C

ONNECTIONS

The eight camera input BNC connectors are labeled “DUAL/LOOP” since they serve two purposes. The
factory default configuration is “DUAL” and each BNC is an independent camera input (75 Ohm
termination is ON). Four DIP switches inside the unit (see section below) determine whether each pair of
inputs are independent (“DUAL”) or used as a loop-through (“LOOP”).

Connect the “VCR IN” BNC to the video output of the VCR and the “VCR OUT” BNC to the video input of
the VCR.  The alarm connector is a standard DB-15 which will mate with an alarm wire adapter board or
standard computer-type cable.  See page 18 for further alarm connection information.

1

5

6

9

1

8

9

15

SERIAL PORT

ALARM

12

VAC

VCR

VCR

VIDEO

1

5

2

6

3

7

4

8

IN

 OUT

OUT

2.0 AMP

DUAL / LOOP

DUAL / LOOP

DUAL / LOOP

DUAL / LOOP

BACK PANEL

Monitor

MADE

IN U.S.A.

V

IDEO 

L

INE 

T

ERMINATION 

S

WITCHES

Loopthrough

Loopthrough

Loopthrough

Loopthrough

Camera 7

Camera 6

Camera 5

Camera 8

Camera 4

Camera 3

Camera 2

Camera 1

VCR

unused

unused

unused

ON

1

2

3

4

ON

1

2

3

4

ON

1

2

3

4

ON

1

2

3

4

SW4

SW3

SW2

SW1

The video line termination switches for each camera input are located in the rear of the unit and are
accessed by removing the top cover.  The switches are in the order shown above when looking toward the
back panel. The above switches are shown in the factory default settings (camera loop-through OFF, 75
Ohm terminations ON).  When turned on, camera loop-through connects together the camera inputs on
the same switch (i.e. the left-most loop-through switch connects camera 4 to camera 8).  When an input is
in “loop-through”, the QSP-860MPX is unable to recognize that the two loop-through inputs are the same
camera image. For multiplexing to behave as expected, one of the two loop-through inputs should be
disabled using the on-screen QSP-860MPX “Sequencing set up” menu (see pages 10, 11

Dip switch positions 2 and 3 on all four groups of switches (SW1 through SW4) control the application of
the 75 Ohm termination impedances for each of the eight camera inputs. The above switches show the
factory default position where all eight camera inputs are terminated with 75 Ohm impedances. Also note
that there is an additional termination switch for the VCR input which is on position 4 of SW 4.

Содержание QSP-860MPX

Страница 1: ...and installation Printing Revision 11 Version 2 3 For Serial numbers 1808000 and greater 14842 NE 95th Street Redmond Washington 98052 Phone 888 288 7644 425 885 7000 Fax 425 881 7014 Customer Servic...

Страница 2: ...nce Set Up 10 Dwell Adjustment 10 Display Sequencing Format 11 Sequencing Format Screens 11 Alarm Options 12 Alarm Enable 12 Alarm Dwell Adjustment 12 Alarm Activation Type 13 Other Options 13 Securit...

Страница 3: ...ach camera is alternately output to the VCR with the factory default set so that each live camera is given an equal number of frames on the tape Dead or unconnected camera inputs will not be recorded...

Страница 4: ...steps are 1 Connect your cameras monitor and VCR to the QSP 860MPX as shown above Refer to the Back Panel Connections and Video Termination Switches sections on the next page for proper connections an...

Страница 5: ...computer type cable See page 18 for further alarm connection information 1 5 6 9 1 8 9 15 SERIAL PORT ALARM 12 VAC VCR VCR VIDEO 1 5 2 6 3 7 4 8 IN OUT OUT 2 0 AMP DUAL LOOP DUAL LOOP DUAL LOOP DUAL...

Страница 6: ...quish Screen Full Frame and back to Single PIP displays How cameras will appear in these displays is programmable See Display Sequence Set Up on page 11 QUADRANT ZOOM This button rotates the orientati...

Страница 7: ...menu Selecting 1 Edits the hour of the day In 24 hour mode 1 through 24 is accepted as entered In 12 hour mode values above 12 will have 12 subtracted from the entered value 2 Edits the minutes field...

Страница 8: ...R from the displayed list The first two entries are for standard 12 and 24 hour steps which will accommodate most VCRs Standard 12 Hr steps is the factory default PIP Pages the list forward for more s...

Страница 9: ...n Since we have a limited set of front panel buttons all of the buttons except DISPLAY and VCR are used to input characters Using the legend any character can be entered in the present character locat...

Страница 10: ...era s video is shown A Record Only camera s video is still multiplexed Selecting 1 8 Toggles the camera s live display from Display on Monitor to Record Only The default is Display on Monitor In the e...

Страница 11: ...ending numerical order and cameras cannot be repeated For example if the pattern 7 5 2 4 5 5 7 were entered the software will translate this to 2 4 5 7 Display Sequence Set Up 1 Hold Each Image for 3...

Страница 12: ...splay will determine how long a continuous alarm camera will be displayed This can be adjusted so that a continuous alarm will not consume all of the VCR s record time A value of zero factory default...

Страница 13: ...ctivation is defined as follows Contact Closure The alarm pin is connected to a current source either 5V or ground Contact Open The alarm pin is not connected to any current source unconnected pin Log...

Страница 14: ...ence of the Camera Switch Input pulse The default is 2 4 Toggles the VCR Playback Discriminator circuit On Off The playback discriminator should be left On unless you wish to view all recorded frames...

Страница 15: ...he following steps before contacting the factory To program the remote control to work with the QSP 860MPX 1 Ensure that batteries are properly installed in the QSP 860MPX Remote Control 2 Turn on the...

Страница 16: ...icular VCR Satisfactory performance can be obtained by setting up the one or two formats you actually plan to use according to the following basic guidelines What is the Delay Table The delay table is...

Страница 17: ...y table and create a custom delay table select the VCR Set Up menu option 2 from the Main Menu Then select Advanced VCR Options option 4 Select Edit Delay Table option 1 and the menu shown here will a...

Страница 18: ...ven to the limitations introduced by these current limiting resistors The alarm connector on the QSP 860MPX is a DB 15 15 pin connector For ease of installation a breakout adapter is provided with the...

Страница 19: ...impedance If a higher voltage or higher current relay is used an external supply is required Under these conditions the open circuit voltage no alarm on pin 9 must not exceed 30 Vdc and the closed cir...

Страница 20: ...n will cause the QSP 860MPX to freeze current display video BB VCR Button will cause the QSP 860MPX to enter the VCR bypass mode BC n Camera Button n is a number 1 through 8 corresponding to the camer...

Страница 21: ...VT S3100 Sony SVT L200 Sony SVT L400 Sony WatchCorder Toshiba KV5168A Toshiba KV6200A short long Toshiba KV7024 Toshiba KV7168A Toshiba KV7960A short long Toshiba KV8168A Toshiba KV8168AHD Toshiba KV8...

Страница 22: ...Ohms Digital Sampling 512H x 512V x 8 Bits 256 Gray Levels Refresh Rate 30 Fields Per Second EIA 25 Fields Per Second CCIR Electrical Power 12 V AC 2 Amp Safety 110V 60Hz Power Supply UL Listed and C...

Страница 23: ...Year where Year is a two digit representation of the year Conformity is defined as follows 1 No value for the current date will cause any interruption in operation of the product 2 Date based functio...

Отзывы: