Display Sequencing Format

A unique feature of the QSP-860MPX is the option to
customize the display sequence format to suit your
application. You can program a specific selection of
cameras for sequencing.

Selecting:

1.  Enters edit mode for dwell time.

2.  Enters “Full Camera Call Up” format menu.

3.  Enters “Quad” format menu.

4.  Enters “PIP” format menu.

5.  Enters “Dual PIP” menu.

6.  Enters “Split Screen/Squish Screen” format

menu.

Note that any changed camera display sequence will not be applied until the display sequencing mode
is activated by the front panel button.

Sequencing Format Screens

The above screens show the factory default values. The most commonly used sequencing is the full
frame or dual page quad formats as shown above. You can customize any or all formats, and may
have more than one section of a multi-camera display defined for sequencing. For any particular
camera display, cameras are sequenced in ascending numerical order and cameras cannot be
repeated.  For example, if the pattern “7,5,2,4,5,5,7” were entered, the software will translate this
to “. 2 . 4 5 . 7 .“.

 

Display Sequence Set Up

 1: Hold Each Image
                 for:   3 Sec.
 2: Full Camera Call Up . . .
 3: Quad . . .
 4: PIP . . .
 5: Dual PIP . . .
 6: Split/Squish Screen . . .

 PIP: Restore Default Settings
 Camera: Select/Change
 DISPLAY: Previous Menu

     Quad Display Sequence

1: Upper Left:  1 . . . 5 . . .
2: Upper Right: . 2 . . . 6 . .
3: Lower Left:    . . 3 . . . 7 .
4: Lower Right:  . . . 4 . . . 8

Enter Cameras you want
displayed in the sequence

Camera: Select/Change
DISPLAY: Previous Menu

Full Camera Display Sequence

1: Cameras: 1 2 3 4 5 6 7 8

Enter Cameras you want
displayed in the sequence

Camera: Select/Change
DISPLAY: Previous Menu

    PIP Display Sequence

1: Background: As is
2: Insert:     1 2 3 4 5 6 7 8

Enter Cameras you want
displayed in the sequence

Camera: Select/Change
DISPLAY: Previous Menu

 Dual PIP Display Sequence

1: Background: As is
2: Insert 1:   1 2 3 4 5 6 7 8
3: Insert 2:   As is

Enter Cameras you want
displayed in the sequence

Camera:  Select/Change
DISPLAY:  Previous Menu

Split/Squish Display Sequence

1: Left:     As is
2: Right:    1 2 3 4 5 6 7 8

Enter Cameras you want
displayed in the sequence

Camera:  Select/Change
DISPLAY:  Previous Menu

Содержание QSP-860MPX

Страница 1: ...and installation Printing Revision 11 Version 2 3 For Serial numbers 1808000 and greater 14842 NE 95th Street Redmond Washington 98052 Phone 888 288 7644 425 885 7000 Fax 425 881 7014 Customer Servic...

Страница 2: ...nce Set Up 10 Dwell Adjustment 10 Display Sequencing Format 11 Sequencing Format Screens 11 Alarm Options 12 Alarm Enable 12 Alarm Dwell Adjustment 12 Alarm Activation Type 13 Other Options 13 Securit...

Страница 3: ...ach camera is alternately output to the VCR with the factory default set so that each live camera is given an equal number of frames on the tape Dead or unconnected camera inputs will not be recorded...

Страница 4: ...steps are 1 Connect your cameras monitor and VCR to the QSP 860MPX as shown above Refer to the Back Panel Connections and Video Termination Switches sections on the next page for proper connections an...

Страница 5: ...computer type cable See page 18 for further alarm connection information 1 5 6 9 1 8 9 15 SERIAL PORT ALARM 12 VAC VCR VCR VIDEO 1 5 2 6 3 7 4 8 IN OUT OUT 2 0 AMP DUAL LOOP DUAL LOOP DUAL LOOP DUAL...

Страница 6: ...quish Screen Full Frame and back to Single PIP displays How cameras will appear in these displays is programmable See Display Sequence Set Up on page 11 QUADRANT ZOOM This button rotates the orientati...

Страница 7: ...menu Selecting 1 Edits the hour of the day In 24 hour mode 1 through 24 is accepted as entered In 12 hour mode values above 12 will have 12 subtracted from the entered value 2 Edits the minutes field...

Страница 8: ...R from the displayed list The first two entries are for standard 12 and 24 hour steps which will accommodate most VCRs Standard 12 Hr steps is the factory default PIP Pages the list forward for more s...

Страница 9: ...n Since we have a limited set of front panel buttons all of the buttons except DISPLAY and VCR are used to input characters Using the legend any character can be entered in the present character locat...

Страница 10: ...era s video is shown A Record Only camera s video is still multiplexed Selecting 1 8 Toggles the camera s live display from Display on Monitor to Record Only The default is Display on Monitor In the e...

Страница 11: ...ending numerical order and cameras cannot be repeated For example if the pattern 7 5 2 4 5 5 7 were entered the software will translate this to 2 4 5 7 Display Sequence Set Up 1 Hold Each Image for 3...

Страница 12: ...splay will determine how long a continuous alarm camera will be displayed This can be adjusted so that a continuous alarm will not consume all of the VCR s record time A value of zero factory default...

Страница 13: ...ctivation is defined as follows Contact Closure The alarm pin is connected to a current source either 5V or ground Contact Open The alarm pin is not connected to any current source unconnected pin Log...

Страница 14: ...ence of the Camera Switch Input pulse The default is 2 4 Toggles the VCR Playback Discriminator circuit On Off The playback discriminator should be left On unless you wish to view all recorded frames...

Страница 15: ...he following steps before contacting the factory To program the remote control to work with the QSP 860MPX 1 Ensure that batteries are properly installed in the QSP 860MPX Remote Control 2 Turn on the...

Страница 16: ...icular VCR Satisfactory performance can be obtained by setting up the one or two formats you actually plan to use according to the following basic guidelines What is the Delay Table The delay table is...

Страница 17: ...y table and create a custom delay table select the VCR Set Up menu option 2 from the Main Menu Then select Advanced VCR Options option 4 Select Edit Delay Table option 1 and the menu shown here will a...

Страница 18: ...ven to the limitations introduced by these current limiting resistors The alarm connector on the QSP 860MPX is a DB 15 15 pin connector For ease of installation a breakout adapter is provided with the...

Страница 19: ...impedance If a higher voltage or higher current relay is used an external supply is required Under these conditions the open circuit voltage no alarm on pin 9 must not exceed 30 Vdc and the closed cir...

Страница 20: ...n will cause the QSP 860MPX to freeze current display video BB VCR Button will cause the QSP 860MPX to enter the VCR bypass mode BC n Camera Button n is a number 1 through 8 corresponding to the camer...

Страница 21: ...VT S3100 Sony SVT L200 Sony SVT L400 Sony WatchCorder Toshiba KV5168A Toshiba KV6200A short long Toshiba KV7024 Toshiba KV7168A Toshiba KV7960A short long Toshiba KV8168A Toshiba KV8168AHD Toshiba KV8...

Страница 22: ...Ohms Digital Sampling 512H x 512V x 8 Bits 256 Gray Levels Refresh Rate 30 Fields Per Second EIA 25 Fields Per Second CCIR Electrical Power 12 V AC 2 Amp Safety 110V 60Hz Power Supply UL Listed and C...

Страница 23: ...Year where Year is a two digit representation of the year Conformity is defined as follows 1 No value for the current date will cause any interruption in operation of the product 2 Date based functio...

Отзывы: