ATV QSP-860MPX Скачать руководство пользователя страница 10

 

QSP-860MPX:  Instructions for Basic Operation and Installation

Page 10

many frames as medium priority cameras. “Alarm Only” cameras are not recorded unless there is an
alarm input and a live video signal is present. “Alarm Only” cameras, under alarm conditions, will be
multiplexed like any other alarm camera.  Dead or non-existent cameras will not be recorded.

Cameras under alarm conditions have a higher priority than “High Priority” cameras and will be given
twice as many frames.  Even under multiple alarm conditions, all cameras are guaranteed some VCR
frames. Multiplexing of alarmed cameras cannot be disabled without disabling the alarm input itself
(which will prevent both monitor and VCR alarm activity). In the above example, if the alarm for “Alarm
Only” camera #8 were triggered, the multiplexing order would be:

8,1,8,2,8,3,8,5,8,1,8,2,8,4,8,1,8,2,8,3,8,6,8,1,8,2,8,4,8,1,8,2,8,3,8,5,8,1,8,2,8,4,8,1,8,2,8,3,8,6....

Camera Monitor Disable

This menu allows an individual camera to be eliminated
from the monitor live mode display while the camera
continues to be recorded (multiplexed).  A “Record Only”
camera is replaced by the “bar pattern” in live display
modes except during an alarm condition where the
camera’s video is shown.  A “Record Only” camera’s
video is still multiplexed.

Selecting:

1 - 8

Toggles the camera’s live display from
“Display on Monitor” to “Record Only”.
The default is “Display on Monitor”.

In the example shown, Camera 8 is set to “Record Only”
and it’s image will be replaced by the “bar pattern” in live
displays.  Also note that the presence of the camera signal is still detected on any camera set to
“Record Only”.  The “No Video” indication will be given on the live display along with the “bar pattern” if
the camera’s signal is not present.

Display Sequence Set Up

The QSP-860MPX has a programmable display sequence format for display modes that support
sequencing.  The image hold (dwell) time is also programmable.

Dwell Adjustment
Selecting:

1

Selects the dwell time for edit.

While editing:

1 - 8

Used to enter digits “1” through “8”.

PIP

Used for a “0” entry.

QUADRANT

Used for a “9” entry.

DISPLAY

Completes the entry if less than 3 digits
and returns to the previous value if no
digits are entered.

  Display Sequence Set Up

 1: Hold Each Image
                 for:   3 Sec.
 2: Full Camera Call Up . . .
 3: Quad . . .
 4: PIP . . .
 5: Dual PIP . . .
 6: Split/Squish Screen . . .

 PIP: Restore Default Settings
 Camera: Select/Change
 DISPLAY: Previous Menu

      Monitor Disable

 1: Display on Monitor
 2: Display on Monitor
 3: Display on Monitor
 4: Display on Monitor
 5: Display on Monitor
 6: Display on Monitor
 7: Display on Monitor
 8: Record Only
 Camera: Select/Change
 DISPLAY: Previous Menu

Содержание QSP-860MPX

Страница 1: ...and installation Printing Revision 11 Version 2 3 For Serial numbers 1808000 and greater 14842 NE 95th Street Redmond Washington 98052 Phone 888 288 7644 425 885 7000 Fax 425 881 7014 Customer Servic...

Страница 2: ...nce Set Up 10 Dwell Adjustment 10 Display Sequencing Format 11 Sequencing Format Screens 11 Alarm Options 12 Alarm Enable 12 Alarm Dwell Adjustment 12 Alarm Activation Type 13 Other Options 13 Securit...

Страница 3: ...ach camera is alternately output to the VCR with the factory default set so that each live camera is given an equal number of frames on the tape Dead or unconnected camera inputs will not be recorded...

Страница 4: ...steps are 1 Connect your cameras monitor and VCR to the QSP 860MPX as shown above Refer to the Back Panel Connections and Video Termination Switches sections on the next page for proper connections an...

Страница 5: ...computer type cable See page 18 for further alarm connection information 1 5 6 9 1 8 9 15 SERIAL PORT ALARM 12 VAC VCR VCR VIDEO 1 5 2 6 3 7 4 8 IN OUT OUT 2 0 AMP DUAL LOOP DUAL LOOP DUAL LOOP DUAL...

Страница 6: ...quish Screen Full Frame and back to Single PIP displays How cameras will appear in these displays is programmable See Display Sequence Set Up on page 11 QUADRANT ZOOM This button rotates the orientati...

Страница 7: ...menu Selecting 1 Edits the hour of the day In 24 hour mode 1 through 24 is accepted as entered In 12 hour mode values above 12 will have 12 subtracted from the entered value 2 Edits the minutes field...

Страница 8: ...R from the displayed list The first two entries are for standard 12 and 24 hour steps which will accommodate most VCRs Standard 12 Hr steps is the factory default PIP Pages the list forward for more s...

Страница 9: ...n Since we have a limited set of front panel buttons all of the buttons except DISPLAY and VCR are used to input characters Using the legend any character can be entered in the present character locat...

Страница 10: ...era s video is shown A Record Only camera s video is still multiplexed Selecting 1 8 Toggles the camera s live display from Display on Monitor to Record Only The default is Display on Monitor In the e...

Страница 11: ...ending numerical order and cameras cannot be repeated For example if the pattern 7 5 2 4 5 5 7 were entered the software will translate this to 2 4 5 7 Display Sequence Set Up 1 Hold Each Image for 3...

Страница 12: ...splay will determine how long a continuous alarm camera will be displayed This can be adjusted so that a continuous alarm will not consume all of the VCR s record time A value of zero factory default...

Страница 13: ...ctivation is defined as follows Contact Closure The alarm pin is connected to a current source either 5V or ground Contact Open The alarm pin is not connected to any current source unconnected pin Log...

Страница 14: ...ence of the Camera Switch Input pulse The default is 2 4 Toggles the VCR Playback Discriminator circuit On Off The playback discriminator should be left On unless you wish to view all recorded frames...

Страница 15: ...he following steps before contacting the factory To program the remote control to work with the QSP 860MPX 1 Ensure that batteries are properly installed in the QSP 860MPX Remote Control 2 Turn on the...

Страница 16: ...icular VCR Satisfactory performance can be obtained by setting up the one or two formats you actually plan to use according to the following basic guidelines What is the Delay Table The delay table is...

Страница 17: ...y table and create a custom delay table select the VCR Set Up menu option 2 from the Main Menu Then select Advanced VCR Options option 4 Select Edit Delay Table option 1 and the menu shown here will a...

Страница 18: ...ven to the limitations introduced by these current limiting resistors The alarm connector on the QSP 860MPX is a DB 15 15 pin connector For ease of installation a breakout adapter is provided with the...

Страница 19: ...impedance If a higher voltage or higher current relay is used an external supply is required Under these conditions the open circuit voltage no alarm on pin 9 must not exceed 30 Vdc and the closed cir...

Страница 20: ...n will cause the QSP 860MPX to freeze current display video BB VCR Button will cause the QSP 860MPX to enter the VCR bypass mode BC n Camera Button n is a number 1 through 8 corresponding to the camer...

Страница 21: ...VT S3100 Sony SVT L200 Sony SVT L400 Sony WatchCorder Toshiba KV5168A Toshiba KV6200A short long Toshiba KV7024 Toshiba KV7168A Toshiba KV7960A short long Toshiba KV8168A Toshiba KV8168AHD Toshiba KV8...

Страница 22: ...Ohms Digital Sampling 512H x 512V x 8 Bits 256 Gray Levels Refresh Rate 30 Fields Per Second EIA 25 Fields Per Second CCIR Electrical Power 12 V AC 2 Amp Safety 110V 60Hz Power Supply UL Listed and C...

Страница 23: ...Year where Year is a two digit representation of the year Conformity is defined as follows 1 No value for the current date will cause any interruption in operation of the product 2 Date based functio...

Отзывы: