3-AXIS INFRARED - LED
PLASTIC DOME CAMERA
540TV Lines
uper High Resolution
S
Infrared - LED Dome Camera
Страница 1: ...3 AXIS INFRARED LED PLASTIC DOME CAMERA 540TV Lines uper High Resolution S Infrared LED Dome Camera...
Страница 2: ...ACCURATE IN ALL RESPECTS HOWEVER WE CANNOT ASSUME RESPONSIBILITY FOR ANY CONSEQUENCES RESULTING FROM THE USE THEREOF THE INFORMATION CONTAINED HEREIN IS SUBJECT TO CHANGE WITHOUT NOTICE REVISIONS OR...
Страница 3: ...several days or more To disconnect the cord pull it out by the plug Never pull the cord itself Allow adequate air circulation to prevent internal heat build up Do not place the unit on surfaces rugs b...
Страница 4: ...NCE TO RADIO COMMUNICATIONS OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXP...
Страница 5: ...er than that specified 17 17 CAUTION these servicing instructions are for use by qualified service personnel only to reduce the risk of electric shock do not perform any servicing other than that cont...
Страница 6: ...NG CAMERA MODULE BASE INSTALLATION STRUCTURE OF THE SETUP MENU OPERATING CAMERA LENS ADJUSTMENT DC AUTO IRIS LENS TROUBLESHOOTING AND MAINTENANCE SPECIFICATIONS EXTERNAL DIMENSION BASIC CAMERA INSTALL...
Страница 7: ...60 1 50 1 120 000 and manual electronic shutter modes OSD On Screen Display Digital Noise Reduction Auto Function DNR Auto and manual white balance modes BLC Back Light Compensation Day Night Auto DA...
Страница 8: ...ide area monitoring 2 Power 24V AC input 12V DC input power source from a DC 12V or AC 24V ac 10 60 50Hz 1Hz Use Certified Listed Class 2 power supply transformer only If using DC 12V power adaptor us...
Страница 9: ...ALLATION TOP Unpack and identify the following parts from the product carton Note Arrow mark indicates the top of the camera image D Anchor Note Make sure the power is turned off when connecting the p...
Страница 10: ...180 IR ame only c ra Sensor Cap At extreme tilt angles Use this to cover a sensor if it points inside the housing Screw Taptite FC M3x6 Camera lens can be moved horizontally or vertically and freely s...
Страница 11: ...g holes and cable hole in the place ceiling to which this dome camera is installed using the Drilling guide label Dome window To remove dome cover turn the dome cover counterclockwise until locators r...
Страница 12: ...ten Mounting screws 2X and align the dome camera with it like above picture Turn the dome camera to left direction about 16 degree 3 The assembly of the dome window cover is in reverse order of disass...
Страница 13: ...NS BRIGHTNESS BACKLIGHT SHUTTER AGC SENSE UP WB MODE RED CONT BLUE CONT PUSH AUTO DETECT MODE DETECT AREA SENSITIVITY ALARM TIME AREA MASK LEVEL TOP DOWN LEFT RIGHT TITLE NEGA POSI SHARPNESS MIRROR ZO...
Страница 14: ...SPLAY each have a SUB MENU and are selected using the UP DOWN buttons The SUB MENUS are displayed by LEFT RIGHT 2 SYNC AUTO or INT can be selected 4 To EXIT the menu use the LEFT RIGHT buttons when EX...
Страница 15: ...0 1 1000 1 2000 1 4000 1 10000 can be selected It becomes 1 60 at NTSC It becomes 1 50 at PAL AGC AGC OFF LOW MID HIGH can be selected 5 6 SENSE UP OFF x2 x4 x8 x16 x32 can be selected SENSE UP helps...
Страница 16: ...an change R and B Gain manually MANUAL To adjust R and B Gain press LEFT or RIGHT button and use UP and DOWN button 2 RED CONT When set to MANUAL 0 to 127 can be selected Another becomes NOT USE 3 BLU...
Страница 17: ...to the COLOR mode or B W mode by the internal IR sensor s signal 2 AUTO LEVEL When set to AUTO the 0 to 18 values can be selected It changes by setting AGC AGC OFF NOT USED AGC LOW 0 to 3can be select...
Страница 18: ...n becomes invalid while displaying OSD However it becomes effective only at MOTION AREA 2 DETECT AREA MOTION AREA is displayed 3 SENSITIVITY 0 to 8 can be selected 4 ALARM TIME 1 to 60 sec can be sele...
Страница 19: ...nsparent the area becomes active Default is ALL transparent it is ALL active When it is light gray the area becomes inactivity Cursor moved by LEFT or RIGH When UP or DOWN is pushed it becomes active...
Страница 20: ...can be selected 5 DOWN When MASK is ON 5 to 126 NTSC or 8 to 152 PAL can be selected 6 LEFT When MASK is ON 0 to 187 NTSC or 0 to 185 PAL can be selected 7 RIGHT When MASK is ON 2 to 189 NTSC or 2 to...
Страница 21: ...ected When PAN TILT is ON it is NOT USE 6 PAN TILT OFF or ON x2 can be selected When OSD MENU is OFF and PAN TILT is ON operate by UP DOWN LEFT RIGHT 7 PHASE Sync phase is adjustable in line lock mode...
Страница 22: ...ushed by BS Erase the character POS Change the position of the title If you want to change the position of the title press ENTER button at the POS Find the position you wish to display the title by us...
Страница 23: ...SPLAY mode 1 TITLE ON or OFF can be selected 2 MOTION DET ON or OFF can be selected 3 RETURN Return to MAIN MENU ON OFF ON OFF DISPLAY TITLE MOTION DET RETURN Video out check Video out Cable U P D N O...
Страница 24: ...View Focus Adjust lens focus from near N to infinity N T W Adjust Focus Adjust Angular Field View DC AUTO IRIS LENS Image Size 1 3 CCD Focal Length Aperture Ratio Angular Field of View 4 9mm DIAGONAL...
Страница 25: ...k Adjust the contrast feature of the monitor Is the camera exposed to strong light If so change the camera position The image on the screen flickers Does the camera face directly into the sun or fluor...
Страница 26: ...Lens Connector etc PAL Video output Operating Temperature 1 0 Vp p 75 ohm composite DC ELC ATW AWC MANUAL OFF x2 x4 x8 x16 x32 ON OFF OFF ON 4 point POSI NEGA OFF ON Sensitivity Alarm time Selective B...
Страница 27: ...Size Cable Entry Weight Unit Shipping 2 6L x 1 65W x 1 65H in 6 5L x 4 2W x 4 2H cm Unit mm 0 1 in 2 5mm thick impact resistant P C LEXAN 3 93 in 10 0cm diameter Two 0 3 0 8cm and one 0 5 1 3cm openin...
Страница 28: ...50302297C 540TV Lines Super High Resolution Infrared LED Dome Camera...