Attwood Sahara 4505-1 Скачать руководство пользователя страница 1

4505 / 4507 / 4511 Installation Instructions

SAVE THESE INSTRUCTIONS

Form Number 69370 Rev. C

03-10

Sahara Series Automatic
Bilge Pumps

3

®

This product carries the standard Attwood three-year warranty.

See www.attwoodmarine.com or Product Catalog for details.

CAUTION:

Read all instructions carefully before installing and using this product.

This pump is sealed and, therefore, submersible. However, the
electrical wire connections must not be submerged. For extra
protection, coat the butt joints and adjacent wire ends liberally with
liquid electrical tape such as MDR

®

 or Starbrite

®

.

Specifications

0 ft.

3.3 ft.

6.7 ft.

10kPa

20kPa

Head

Head

Head

Head

Head

Max Head

Part

Amp

GPH/

GPH/

GPH/

LPH/

LPH/

([email protected]/

Num.

Model

Fuse amps

amps

amps

amps

amps

kPa@12v)

4505

S500

2.0

500/1.5

350/1.4

200/1.4

1136/1.2

598/1.2

9'/24

4507

S750

5.0

750/3.0

625/2.8

450/2.8

1817/2.5

1306/2.5

16'/36

4511

S1100 6.0

1100/4.0

970/3.8

750/3.8

3104/3.3

2328/3.3

11'7"/28

WARNING: To prevent injury, always disconnect the power

source when installing or servicing any electrical product.

DO NOT use pump to remove gasoline, oil or other flammable liquids.

Always use the fuse amperage rating specified for your pump model.
Failure to do so could result in serious personal injury or fire hazards.

Attwood bilge pumps are designed to exhaust 

STANDING WATER

ONLY. They are not intended to prevent rapid accumulation of
on-board water due to rough weather, hull damage, and/or other
unsafe navigational conditions.

REQUIRED MATERIALS

Hose and thru-hull fittings, available separately from Attwood:
Sahara Model 4505 and 4507–
3/4" I.D. hose: Attwood No. 4199 (includes 2 clamps)
3/4" I.D. thru-hull: No. 3873 (straight), No. 66541 or 66547
(stainless steel straight), No. 3877 (90

°

), or No. 3878 (double-end)

Sahara Model 4511–
1-1/8" I.D. hose: No. 11551 (clamps not included)
1-1/8" I.D. thru-hull: No. 3874 (white), No. 3874A (black) or
No. 66543, 66549 (stainless steel), or No. 3879 (90

°

)

Two (2) hose clamps suitable for (3/4" or 1-1/8") hose.

AUTO/OFF/MANUAL dash-mounted control switch
(Attwood No. 7615A).

In-line fuse connector (Attwood No. 14341) and appropriate
size fuse.

Three (3) stainless steel #6 x 1/2" self-tapping screws, round
or pan head. Use a #32 drill bit for pilot holes.

Four (4) wire butt-connectors for 16-gauge wire.

Two (2) insulated spade terminal connectors for 16-gauge wire.

Suitable means to make electrical connections waterproof.

Cordless drill.

Screwdriver.

ISO Specifications

12.0-volts DC

(LPH=Liters Per Hour)

ABYC Specifications

13.6-volts DC

(GPH=Gallons Per Hour)

OPTIONAL MATERIALS

1/2"-thick marine plywood block (slightly larger than pump base).

Waterproof adhesive (epoxy, silicone adhesive, or fiberglass
resin) to mount block.

16-gauge wire (brown and black).

PUMP MOUNTING INSTRUCTIONS

WARNING: Remove the pump mounting base (See Figure 3).

Remove the foam block that supports the float during shipping.
Failure to do this prevents the pump from starting when water
is present.

1. Make sure the hull thickness is at least 1/2" thick. If not, place a

block of 1/2" marine plywood (slightly larger than pump base) in
the lowest part of the bilge. Be sure that the pump cover can be
removed for cleaning in this position. Glue the plywood to the
hull with a waterproof adhesive (epoxy, silicone adhesive, or
fiberglass resin). See Figure 1.

2. Position the pump in the lowest part of the bilge on a flat, level

surface (on the plywood block if it has been installed) with the
outlet pointing toward the transom.

3. Be sure outlet nozzle is level. If pointed upward or downward,

an airlock may form in the pump. (See Figure 1.)

4. The float end of the pump must be level with or above the

pump end (See Figure 1). This prevents the pump from running
out of water while the float is still high enough to activate the pump.

5. Mark location of the three (3) mounting holes with a pencil

or scribe.

  WARNING: When drilling holes do not drill through the hull!

6. Carefully drill two 1/8" diameter pilot holes in marked area and

drive a screw in each hole.

7. Slide hose clamps (one to clamp hose to the pump, the other for

the thru-hull connector) over end of the hose. Force hose over
the discharge nozzle of the pump. Install clamp.

8. Route hose on an upward incline to the thru-hull connector.

Avoid dips in hose that can trap water and airlock the pump.
Avoid putting excess tension on hose, which can damage the
pump outlet.

9. Force the hose over the thru-hull barbs and clamp into place.

THRU-HULL CONNECTOR INSTRUCTIONS

If no thru-hull connector exists, choose a location for the fitting.

1. Position thru-hull fittings at least 12" above the water line to

prevent water from coming back into the hull. On sailboats,
mount the thru-hull high enough on the center of the transom
to be above the water line at all times.

2. Place fitting, if possible, on the same side as the steering wheel

so the driver can see discharge of water when the pump is
working properly.

3. Drill hole to match outside diameter of the thru-hull

connector thread.

4. Place a small bead of suitable marine sealant around inside

of the thru-hull connector flange.

Figure 1

Toward Bow

Float End
Of Pump

1/2" Thick
Mounting Block

Pump Outlet
Pointing To Transom

Transom

Parallel To

Bottom Of Boat

Level

Содержание Sahara 4505-1

Страница 1: ...lons Per Hour OPTIONAL MATERIALS 1 2 thick marine plywood block slightly larger than pump base Waterproof adhesive epoxy silicone adhesive or fiberglass resin to mount block 16 gauge wire brown and black PUMP MOUNTING INSTRUCTIONS WARNING Remove the pump mounting base See Figure 3 Remove the foam block that supports the float during shipping Failure to do this prevents the pump from starting when ...

Страница 2: ...ounted high and dry Do not use household cleaners on the pump because many of them may damage the pump materials ATTWOOD LIMITED WARRANTY ATTWOOD CORPORATION 1016 North Monroe Lowell Michigan 49331 Attwood warrants to the original consumer purchaser that Attwood brand products will be free from defects in materials and workmanship under normal use and service for three years from the date of origi...

Страница 3: ...éable époxyde adhésif à la silicone ou résine de fibre de verre pour la fixation du bloc Filage de calibre 16 brun et noir DIRECTIVES DE FIXATION DE LA POMPE AVERTISSEMENT Retirez la base de fixation de la pompe voir la figure 3 Retirez le bloc en mousse qui soutient le flotteur en cours d envoi Le fait de ne pas le faire préviendra le démarrage de la pompe en présence d eau 1 Assurez vous que l é...

Страница 4: ...r la base Assurez vous que les languettes sont insérées à fond Vérifiez de temps à autre les raccords électriques pour assurer qu ils sont bien imperméables et qu ils sont fixés en position élevée et bien sèche Évitez d utiliser des produits nettoyants domestiques pour nettoyer la pompe Plusieurs d entre eux risquent d endommager le matériel dont est fabriquée la pompe GARANTIE LIMITÉE ATTWOOD ATT...

Отзывы: