FibreBridge™ 6500

Getting Started Guide

Thank you for purchasing an ATTO FibreBridge. This guide gives you the basics for installing 
and configuring your FibreBridge. For more information, refer to the 

FibreBridge Installation 

and Operation Manual

Examine the contents of your FibreBridge 
packing box. If any of the items listed below 
are missing, contact your ATTO 
representative.
• The FibreBridge. Note the serial number of 

your FibreBridge unit: 
________________________

• Power cord(s)
• “L” brackets for mounting in a 19” rack
• Ethernet cable
• RS 232 cable

 1 Install the FibreBridge

Note

Please visit the download section of www.attotech.com for 
Firmware, Installation and Operation Manual, 
QuickNAV™ IP discovery program and system drivers

1.1 Place the FibreBridge on a stable flat 

surface, install it into a standard rack or 
into your device.If installing the 
FibreBridge 6500 into a rack, see Exhibit 
1 and follow these instructions:

 a. Attach “L” brackets so that the front 

side with the LEDs face front and the 
connector side is at the back.

 b. Install the FibreBridge horizontally 

within the rack so it does not reduce the 
air flow within the rack.

1.2 Connect and power up Fibre Channel 

devices from your SAN to the FibreBridge 
using SFPs and multimode fiber optic 
cables for the Fibre Channel ports. Keep 
cable lengths as short as possible to 
ensure the highest signal quality and 
performance. Refer to Cabling in the 
FibreBridge Installation and Operation 
Manual.

1.3 Connect and power up SAS/SATA target 

devices. Refer to Cabling in the 
FibreBridge Installation and Operation 
Manual. 

1.4 Connect the Ethernet port to your 

network.

1.5 Connect power:

 a. Connect the AC power cord(s) from 

the FibreBridge to the proper AC 
source outlet and turn on the power 
using the power switch on each 
receptacle.

Note

The power source must be connected to a protective 
earth ground and comply with local electrical codes. 
Improper grounding may result in an electrical shock 
or damage to the unit.

If you are using a rack:
 a. Properly ground the FibreBridge to the 

rack equipment. The earth ground 
connection must be maintained. 