A
If the flame extinguishes for any reason,
the safety valve will automatically shut
off the gas supply to the burner.
To re-light the burner, first turn the oven
control knob to position
●
, wait for at
least 1 minute and then repeat the
lighting procedure.
ATTENTION: Never turn the thermostat
before pressing the ignition button or
before approaching a flame to the hole
“A” of the floor of the oven.
IGNITION OF THE OVEN BURNER
ATTENTION: Never turn the thermostat
before pressing the ignition button or
before approaching a flame to the hole
“A” of the floor of the oven.
The oven door must be open during
this operation.
To ignite the oven burner:
1 – Open the oven door to the full
extent.
WARNING: Risk of explosion! The
oven door must be open during
this operation.
2 – Lightly press and turn the thermo-
stat knob anti-clockwise to max
position
★
(fig. 4.2), then press the
knob firmly until the burner lights.
Never continue this operation for
more than 15 seconds. If the
burner has still not ignited, wait
for about 1 minute prior to repeat-
ing the ignition.
To light the oven burner manually,
approach a flame to the hole ‘A’ of
the oven floor fig. 4.3.
3 – After lighting the burner, wait a few
seconds before releasing the knob
(until the safety valve stays open).
4 – Gently close the oven door and set
the oven control knob to the
required temperature.