INSTRUCTIONS FOR USE

W W W . A T T A C K . S K

WALL HUNG ELECTRIC BOILER

ATTACK®

ELECTRIC EXCELLENT

Содержание ELECTRIC 08

Страница 1: ...INSTRUCTIONS FOR USE W W W A T T A C K S K WALL HUNG ELECTRIC BOILER ATTACK ELECTRIC EXCELLENT...

Страница 2: ......

Страница 3: ...kdowns 27 3 Installation 3 1 Norms and regulation 28 3 2 Placement of the boiler 28 3 3 Mounting of the boiler on the wall 28 3 4 Electroinstallation 28 3 4 1 Connection of the boiler to electric supp...

Страница 4: ...ation saves also your energy consumption The boiler could be regulated by the room thermostat and it also able to heat sanitary water in an independent storage water tank connected through with 3 ways...

Страница 5: ...ion and according to the project manipulation operation using control and maintenance of the boilers are forbidden if it is not in accordance with rules and directions of this instruction manual It is...

Страница 6: ...6 450 656 345 280 26 16 652 124 176 177 199 G3 4 G 3 4 1 4 Main dimensions Dimensions in mm outlet of heating water inlet of heating water...

Страница 7: ...ater volume of whole boiler l Environmental kind SN 332000 3 Efficiency by nominal output Supply cable CYKY mm 2 5x4 Supply cable AYKY mm 2 5x6 Expansion vessel l Surrounding temperature C Warehousing...

Страница 8: ...control unit frame of the boiler switchboard X2 switchboard X1 safety valve expansion vessel thermomanometer sensor cables bushing main switcher on off pump pressure switcher inlet pipe safety contact...

Страница 9: ...unctions which assure basic characteristics mainly safety functions assure protection against the of health and property user s functions functions set by the user operation functions internal functio...

Страница 10: ...orms and is certified The control unit has a protection against below and over voltage The control unit is protected by system Watch Dog Timer with time 512 ms against its processor blocking In case t...

Страница 11: ...hboard HV main switcher pump ZM earthing bridge PE protective conductor N working conductor L phase conductor TT1 heating element 1 TT2 heating element 2 TT3 heating element 3 L N PE TS 230V HT 230V H...

Страница 12: ...ghtening control 1 level HDO mass remote control GSM GSM modem HT emergency thermostat TS pressure switcher TUV service utility water sanitary water KM1 contactor X1 X2 switchboard HV main switcher pu...

Страница 13: ...external input lightening control 1 level HDO mass remote control GSM GSM modem HT emergency thermostat TS pressure switcher TUV service utility water sanitary water KM1 contactor X1 X2 switchboard HV...

Страница 14: ...l input lightening control 1 level HDO mass remote control GSM GSM modem HT emergency thermostat TS pressure switcher TUV service utility water sanitary water KM1 contactor X1 X2 switchboard HV main s...

Страница 15: ...sure switcher TUV service utility water sanitary water KM1 contactor X1 X2 switchboard HV main switcher pump ZM earthing bridge PE protective conductor N working conductor L phase conductor TT1 heatin...

Страница 16: ...hange of the requested parameter change of the requested parameter sanitary water temperature setting information about instantaneous stage going to mode STAND BY parameters enter selection confirmati...

Страница 17: ...ater mode and TUV sanitary water sensor connected instantaneous temperature in referring room in case of reffering room sensor connection pump operation marking is lightining and the pump is in an ope...

Страница 18: ...boiler is heating the system and also the storage water tank if it is connected through Operation mode summer on the display there is SU this mode is possible to activated by reducing the temperature...

Страница 19: ...etting of temperature in a reference room Press the button on the control panel for setting of the temperature requested press for its increasing or for its decreasing and confirm it by After this con...

Страница 20: ...storage water tanks is controlled directly by connection of TUV sensor in the TUV mode or indirectly with storage thermostat which gives information to the boiler heat don t heat through the connectio...

Страница 21: ...before set temperature 80 C After termination of operation the boiler automatically goes back to the mode before setting Going back to this mode is automatically it is not possible to active it by a...

Страница 22: ...1 50 Producer 1 P19 I constant Regulation constant I 0 to 99 step1 50 Producer 1 P20 HW hysteresis Hysteresis of heating water temperature 1 to 10 step1 C 5 Service 1 P21 DHW hysteresis Hysteresis of...

Страница 23: ...pump running out after termination of request for heating Remarks In case that the request for heating of sanitary water is terminated in winter operation mode there is activated time pump running out...

Страница 24: ...deblocated by the parameter P11 then the parameter P12 is not active The value 1 to 60 time in minutes for setting of lag delay P18 Selection of regulation constant P selection of regulation constant...

Страница 25: ...the nominal output will be lighted in case of the signal of 1st level from the lightening relay placed in consumer board unit Value 0 half the max power output a step by the set value of parameter P3...

Страница 26: ...mote GSM communication with the boiler through SMS The number has to be inserted in the international number format and if the number is shorter than 13 places then it is necessary to insert for free...

Страница 27: ...rvoltage on the inlet clamps of the control unit Call service Err4 99 More than 1 breakdown in one time More than 1 breakdown in one time failures are displayed in turns Call service Table of errors b...

Страница 28: ...protection and safety the rule SN 06 1008 is valid and there is stated minimal distance from flammable objects We recommend enlarging these distances to have minimal space easier service and manipula...

Страница 29: ...cover of the boiler to avoid its dismantling For GSM modem mounting use inlets on the upper cover of the boiler If you have a not strong GSM signal from network then it is possible to buy additional e...

Страница 30: ...below the margined signed on the thermomanometer For right boiler and heating system operation is necessary to control the overpressure value sometimes and in case that the value is on requested valu...

Страница 31: ...er The user is able to clean surface of the cover with detergents and control operation modes or fill heating water to the system checked by water pressure dawn according to the value on the thermoman...

Страница 32: ...the company which put your boiler into operation or by guarantee repair companies stated in the list of guarantee place Apply condition stated in the guarantee list Your claim is not valid without fu...

Страница 33: ...33 10 2 c b relays mode Control unit and TUV sanitary water mode diagram a control unit TUV sanitary water mode Common Close Open TUV NTC TUV 230V...

Страница 34: ...fterthe2ndyearofoperation Stamp signature of the service organization Date Data of the customer legibly Name and surname Street ZIP code town Tel Boilercommissioningcertificate Serial number Date of c...