background image

INFORMER

USER MANUAL

Содержание INFORMER

Страница 1: ...INFORMER USER MANUAL ...

Страница 2: ......

Страница 3: ...r Ÿ Stores 4 Users 1 Admin Contact No Ÿ Sms and or Calls To 5 Authorized Users Ÿ Editable 15 Bit Sms Alert Message Ÿ Zone Open Close Or Both Instant Alert Ÿ 2 Ways Of Control Sms Ÿ LED Indicators For Network Signal Status Ÿ Zone Arm Disarm Through Sms Android Apps Ÿ Compact Design Arming Disarming through SMS Mobile Call Alert 1 Trigger Store 4 Phone Numbers EMERGENCY Switch ...

Страница 4: ...TCH Informer is a Eight trigger GSM communicator which can send SMS and make dummy call when trigger is in open close condition This device can be controlled through SMS Android application USER MANUAL INFORMER 1 2 3 4 5 6 7 8 PW ST NW 2 3 1 4 ...

Страница 5: ...D will glow when Zone is in open condition Ÿ Will glow when system is ON Ÿ Will blink while system is sending receiving SMS Ÿ Will be in green color in Deactive state Ÿ Will be in Red color in Active state Ÿ Will blink slowly when network is good Ÿ Will blink fast when network is bad SET BALANCE COMMAND Ÿ You would get a reply message with balance details Ÿ Type BAL xxx and send to Informer from A...

Страница 6: ...ess Ÿ Likewise you would get P3 P4 P5 SUCCESS message when adding those numbers SET ALERT MESSAGE Ÿ Likewise add MSG2 MSG3 MSG4 MSG5 MSG6 MSG7 MSG8 Ÿ You can add 8 messages for eight zones Ÿ Type MSG1 12 text message and send to Informer from Admin number MSG1 12 TEXT MESSAGE Ÿ You would get reply message M1 SUCCESS which confirms the process M1 SUCCESS MSG2 12 TEXT MESSAGE MSG8 12 TEXT MESSAGE PHO...

Страница 7: ...rms the process CLOSE ALERT ALT CCCCCCCC SALT CCCCCCCC SUCCESS Ÿ For Close alert Type ALT CCCCCCCC and send to Informer from Admin number Ÿ You would get a reply message SALT CCCCCCCC SUCCESS which confirms the process BOTH OPEN CLOSE ALERT ALT SSSSSSSS SALT SSSSSSSS SUCCESS Ÿ For Both Open Close alert Type ALT SSSSSSSS and send to Informer from Admin number Ÿ You would get a reply message SALT SSS...

Страница 8: ...f you want Zone 1 close c Zone 2 both s Zone 3 close c Zone 4 both s Zone 5 open o Zone 6 close c Zone 7 open o Zone 8 close c Just Type ALT CSCSOCOC and send to Informer from Admin number Likewise you can set alert conditions which you want for each ZONES Ÿ You would get a reply message SALT CSCSOCOC SUCCESS Which confirms the process ...

Страница 9: ...number Ÿ You would get a reply message CS SUCCESS ONLY CALL ALERT CS YN CS SUCCESS Ÿ For only call alert Type CS YN and send to Informer from Admin number Ÿ You would get a reply message CS SUCCESS ONLY SMS ALERT CS NY CS SUCCESS Ÿ For only sms alert Type CS NY and send to Informer from Admin number Ÿ You would get a reply message CS SUCCESS ...

Страница 10: ...ct the Zones which you want to assign to Phone number 1 Ÿ Example If you want Phone number 1 to get alerts of zones 2 3 4 8 o Type ZP1 2348 and send to informer number Ÿ You Would Get reply Message SZP SUCCESS Which Confirms the process ZP ZP P1 12345678 P2 P3 P4 P5 SZP SUCCESS ZP1 2348 The Device has memory available to store 5 Phone numbers which includes 1 admin number You can Assign all 5 Phone...

Страница 11: ...IVATE ALERTS FOR PHONE NUMBERS Ÿ To Deactivate the Zone Alerts For Phone number 1 Type ZP1 D and send to informer number Ÿ You Would Get a reply Message as SZP1 D SUCCESS Which Confirms the Process Ÿ Like Wise you can Deactivate Zone alerts For other phone numbers using commands o ZP2 D for Phone Number 2 o ZP3 D for Phone Number 3 o ZP4 D for Phone Number 4 o ZP5 D for Phone number 5 ZP1D SUCCESS ...

Страница 12: ...P1 A SUCCESS Which Confirms the Process Ÿ Like Wise you can Activate Zone alerts For other phone numbers using commands o ZP2 A for Phone Number 2 o ZP3 A for Phone Number 3 o ZP4 A for Phone Number 4 o ZP5 A for Phone number 5 ZP1A SUCCESS ZP1 A ZP3 A ZP5 A ZP2 A ZP4 A After Deactivating Once again If you wish to activate alerts for Particular phone numbers Follow below Commands ...

Страница 13: ... a reply message S A C T A S U C C E S S w h i c h confirms Activation TO ACTIVATE INDIVIDUAL ZONES ACT 2468 SACT SUCCESS Ÿ To Activate individual Zones Type ALT Zones which you want to Activate and send to Informer from Admin number Ÿ For example if you want to Activate ZONES 2 4 6 8 Type ALT 2468 and send to Informer from Admin number Ÿ You would get a reply message SACT SUCCESS which confirms Act...

Страница 14: ...d get a reply message SDAA SUCCESS which confirms Deactivation TO DEACTIVATE INDIVIDUAL ZONES DA 2468 SDAA SUCCESS Ÿ To Deactivate individual Zones Type DA Zones which you want to Deactivate and send to Informer from Admin number Ÿ For example if you want to Deactivate ZONES 2 4 6 8 Type ALT 2468 and send to Informer from Admin number Ÿ You would get a reply message SDAA SUCCESS which confirms Deact...

Страница 15: ...rmer from Admin number Ÿ You would get a reply message with status of Informer TO CHECK BALANCE BAL BL M A Bal Rs 00 09 M A Val 01 Jan 2020 Ÿ To check Balance Type BAL and send to Informer from Admin number Ÿ You would get a reply message with balance details ST Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 SMS CALL ...

Страница 16: ...TO CHECK ALERT MESSAGE STORED MSG Ÿ To check alert message stored Type MSG and send to Informer from Admin number Ÿ You would get a reply message with alert message stored in Informer PR P1 XXXXXXXXX P2 XXXXXXXXX P3 XXXXXXXXX P4 XXXXXXXXX P5 XXXXXXXXX MR M1 12 TEXT MESSAGE M2 12 TEXT MESSAGE M3 12 TEXT MESSAGE M4 12 TEXT MESSAGE M5 12 TEXT MESSAGE M6 12 TEXT MESSAGE M7 12 TEXT MESSAGE M8 12 TEXT M...

Страница 17: ... reply message as P1 SUCCESS which confirms Admin change USER MANUAL INFORMER How to Reset Informer RST RT Master Reset SUCCESS Ÿ To Reset Informer Type RST and send to Informer from Admin number Ÿ You would get a reply message RT Master Reset SUCCESS which confirms the process Ÿ Once RESET all stored numbers and settings will be deleted Admin number will remain same ...

Страница 18: ...ADD PHONE NUMBERS ALERT MESSAGE ALERT CONDITION ACTIVATION DEACTIVATION TO CHECK PHONE NUMBERS STORED TO CHECK ALERT MESSAGE STORED TO CHECK STATUS ALERT TYPE Ÿ Notes Ÿ You would get all sms commands as a message when you send any wrong commands to Informer Ÿ If operations are not successful you would get FAILED message as reply ...

Страница 19: ...ble GSM Antenna ENVIRONMENTAL Environment Max Humidity Operating Temperature Storage Temperature PHYSICAL Colour Control Panel Dimensions mm Weight 24 watts 12 24 V 2 amp max 500 Millisecond 5 kilo Ohm For Normally Closed 150 m Depends on cable resistance 3 db Residential Commercial Light Industrial 95 Non Condensing 0 C To 45 C 20 C 60 C RED BLACK H X W X L 115 X 25 X 110 125 g ...

Страница 20: ...V V 1 2 3 4 PW 5 ST 6 NW 7 8 SIM INSERT I n f o r m e r BOARD SIZE L 75 mm H 75 mm ADAPTOR INPUT 220V OUTPUT 12 V 2A INVERTER POWER FRONT DOOR FRONT DOOR FRONT DOOR ZONE 1 ZONE 8 ZONE 2 ZONE 7 ZONE 3 ZONE 6 ZONE 4 ZONE 5 FRONT DOOR DOOR SENSOR DOOR SENSOR DOOR SENSOR DOOR SENSOR DOOR SENSOR DOOR SENSOR DOOR SENSOR DOOR SENSOR ...

Страница 21: ... Date Signature How To Obtain Warranty Service No 40 Muthumariamman Koil St Navalar Nagar Anna Nagar West Chennai 600 040 India INFORMER You must present your Warranty Card and a copy of your original sales receipt to validate warranty coverage DO NOT lose your receipt ...

Отзывы: