Troubleshooting
SuperTrak™ GEN3 System Operation and Maintenance Manual
263
Rev. 9 (12-2021)
Test Manually with TrakMaster
During this test, a pallet is manually commanded across the straight section or
180 deg. section being tested and across the sections on either side of the straight
section or 180 deg. section being tested.
1. Prepare the system and SuperTrak pallets:
a. Verify that no system tooling can interfere with pallet motion. If
required, block the system tooling out of the way.
b. Remove all pallets from the straight section or 180 deg. section to be
tested and the sections on each side of it.
c. Position a pallet directly on the right or left side of the section to be
tested.
2. Open TrakMaster.
3. In the left pane, click
Diagnostic
>
Pallet
.
4. At the top of the screen, click
or
to select the
Section
that
contains the pallet to use for the
test.
The selected pallet graphic has a
red outline.
5. Click the
Configuration
tab.
6. Note the value of the
Velocity
parameter, so that you can change
the value back to this after the
test.
Before starting this test, manually block any system tooling that could
interfere with pallet motion. Failure to do so, could result in system
damage.
Содержание SuperTrak GEN3
Страница 1: ...Rev 9 December 2021...
Страница 2: ......
Страница 3: ...SuperTrak GEN3 Conveyance Platform Modular Conveyor Operation and Maintenance Manual...
Страница 6: ......
Страница 12: ...This page is intentionally blank...
Страница 30: ...This page is intentionally blank...
Страница 58: ...This page is intentionally blank...
Страница 296: ...This page is intentionally blank...
Страница 300: ...This page is intentionally blank...
Страница 364: ...This page is intentionally blank...
Страница 366: ...This page is intentionally blank...