Replace an Encoder Assembly
A 180 deg. (800 mm) section has four (4) encoder assemblies, while all other
curved and straight sections have two (2) encoder assemblies. Replace the
encoder assembly if a SuperTrak conveyance platform fault indicates that
replacement is required.
Remove an Encoder Assembly - Straight Section
1. Turn the
SuperTrak conveyance platform power disconnect switch
to
the OFF position.
2. Lock out and tag hazardous energy.
3. Remove the five (5) encoder assembly screw caps.
4. Remove the five (5) encoder assembly screws.
5. Lift the encoder assembly straight up, off the two locating dowels.
6. Disconnect the RJ11 plug from the
encoder assembly connection.