Technician Procedures
Replace a Coil Driver Board
This section describes how to replace a coil driver board in a straight section or in
a 180 deg. section.
Remove a Coil Driver Board - Straight Section
1. Turn the
SuperTrak conveyance platform power disconnect switch
to
the OFF position.
2. Lock out and tag hazardous energy.
3. Use a flat head screwdriver to unlock the
five (5) locks, and then open the electrical
door.
4. Unplug the two (2) ribbon cables.
Pull each of the four (4) ribbon cable plugs
straight out.
5. Unplug the five (5) coil plugs.
Pull each coil plug straight out.
To prevent electrical board damage from electrostatic discharge (ESD),
use an ESD wrist strap when working with the coil driver board. An ESD
wrist strap prevents the buildup of static electricity.