110
SuperTrak™ GEN3 System Operation and Maintenance Manual
Rev. 9 (12-2021)
Installation
Install an IR Reader Mount Assembly
The IR reader mount assembly can be installed in one of the following locations:
•
Custom location, if it meets the following criteria:
•
The air gap between the IR reader and IR tab is 1 mm (0.039 in.).
•
The IR reader is located in front of the SuperTrak conveyance platform
section that it is plugged into.
•
There is no interference with a straight section electrical door.
•
Across the joint of two (2) adjacent straight sections. This installation location
prevents interference with the electrical door of the straight section.
During this procedure, make sure the clamp plate (see “G” in the diagram
below) is positioned between the clamp bolts and the joint plate when
you slide the long side of the IR reader mount assembly under the joint of
the two (2) adjacent straight sections. Failure to do so will result in joint
plate damage.
A
Pallet
E
Air gap adjustment screw (with
slotted hole)
B
1 mm (0.39 in.) air gap
F
Clamp plate bolt (1 of 2)
C
IR tag (read-only)
G
Clamp plate
D
IR reader
H
IR reader mount assembly
Содержание SuperTrak GEN3
Страница 1: ...Rev 9 December 2021...
Страница 2: ......
Страница 3: ...SuperTrak GEN3 Conveyance Platform Modular Conveyor Operation and Maintenance Manual...
Страница 6: ......
Страница 12: ...This page is intentionally blank...
Страница 30: ...This page is intentionally blank...
Страница 58: ...This page is intentionally blank...
Страница 296: ...This page is intentionally blank...
Страница 300: ...This page is intentionally blank...
Страница 364: ...This page is intentionally blank...
Страница 366: ...This page is intentionally blank...