CS-3000 RF Generator Unit Operator Manual

AtriCure, Inc.

IFU-0022.A

2021/04

Page 1 / 12

nContact Coagulation System Radiofrequency (RF) Generator Unit - Model CS-3000

2797

AtriCure Incorporated

7555 Innovation Way

Mason, Ohio 45040 USA

Customer Service:

1-866-349-2342 (toll free)

1-513-755-4100 (phone)

Caution: Federal (US) law restricts this device to sale by or on the order of a physician.

Disclaimer

AtriCure reserves the right to change its products and services at any time to incorporate the 

latest technological developments.  This Manual is subject to change without notice.
Although this Manual has been prepared with every precaution to ensure accuracy, AtriCure 

assumes no liability for damages resulting from the application or use of this information.

Trademarks

nContact and the nContact logo are trademarks of AtriCure, Inc.

 

IFU-0022.A

Содержание nContact CS-3000

Страница 1: ...restricts this device to sale by or on the order of a physician Disclaimer AtriCure reserves the right to change its products and services at any time to incorporate the latest technological developments This Manual is subject to change without notice Although this Manual has been prepared with every precaution to ensure accuracy AtriCure assumes no liability for damages resulting from the applica...

Страница 2: ... and Operation 8 Generator Setup and Operation 8 Chapter 3 Cleaning 9 Chapter 4 Technical Specifications and Safety Inspection 9 Device Specifications 9 Environmental Specifications 9 Periodic Inspections 9 Chapter 5 Product Specifications 10 Operational Conditions Front Panel Displays 10 Figure 8 RF Generator Front Panel Display at Power On 10 Figure 9 RF Generator Front Panel Display at Standby ...

Страница 3: ...connect to earthed ground Follow the manufacturer s directions for the placement of the indifferent dispersive electrode and for proper insulation between the patient and any metallic surfaces o Maintain safe handling techniques during electrocoagulation due to electric fields and hot metallic surfaces o Do not touch the electrode surface of the Coagulation Device and the Indifferent Dispersive El...

Страница 4: ...ality should be that of a typical commercial or hospital environment Voltage Dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 Voltage Dips 0 Vt 0 5 cycle At 0 45 90 135 180 225 270 and 315 phase angles 0 Vt 1 cycle and 70 Vt 25 30 cycles Single phase at 0 Voltage interruptions 0 Vt 250 300 cycle Voltage Dips 0 Vt 0 5 cycle At 0 45 90 135 180 225 270 and 31...

Страница 5: ...radiated RF disturbances are controlled The customer or the user of the CS 3000 RF Generator can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the CS 3000 RF Generator as recommended below according to the maximum output power of the communications equipment Rated Maximum Output Power of Transmit...

Страница 6: ...e generator operates in either the Power Control or Diagnostic Evaluation mode When operating in Power Control mode set the desired duration and Power level The generator will transmit Power at the set point for the Time set by the operator Power may be adjusted manually throughout the treatment to tailor the coagulation process but caution should be used when deviating from the recom mended pre s...

Страница 7: ...in impedance Impedance 5 Impedance resistance between the coagulation device and the indifferent dispersive electrode is measured by the generator and displayed in ohms Ω A bar graph shows the change in impedance between the initiation of RF energy baseline and throughout tissue coagulation test As conductivity decreases impedance increases During coagulation of tissue when the temperature of the ...

Страница 8: ...e coagulation device and manufacturer direc tions for the indifferent dispersive electrode CAUTION Failure to achieve good skin contact by the entire adhesive surface of the indifferent dispersive electrode could result in a patient burn or poor electrical performance from the coagulation device Note Patient Return Electrode e g Indif ferent Dispersive Electrode surface area of 21 square inches 13...

Страница 9: ...G Ensure Isopropyl Alcohol IPA is completely dry before oper ating the unit CAUTION Avoid caustic or abrasive cleaners Guidelines The following guidelines are recommended for cleaning the unit It is the user s responsibility to qualify any deviations from these processing methods 1 Disconnect the unit or cart from the outlet before cleaning 2 If the unit and or accessories are contaminated with bl...

Страница 10: ...nd transmit RF energy to the coagulation device The RF ON OFF LED is activated Power is preset for the coagulation devices The cycle Time e g 56 s is displayed in lower right corner and counts up to the set value Impedance is measured and the value displayed in the lower left e g 105 Ω Impedance is graphed in the right Test bar against the baseline value mea sured at initiation of RF The baseline ...

Страница 11: ...rected Once the warning is corrected then the parameters reset to the preset values Final Impedance 765 Ω is displayed and graphed against the baseline 100 Ω Final Percent change in impedance is displayed 665 Final Power transmitted shown 50 W Time at User Termination of RF energy 34 s displayed When this warning occurs an audible tone will sound three times for 1 5 seconds with 450 milliseconds b...

Страница 12: ...ng the use of the nContact Coagulation system please contact Customer Service at AtriCure Incorporated 7555 Innovation Way Mason Ohio 45040 USA Customer Service 1 866 349 2342 toll free 1 513 755 4100 phone EC REP AtriCure Europe B V De Entree 260 1101 EE Amsterdam The Netherlands 31 20 7005560 ear atricure com WARRANTIES Limitation on Liability This warranty and the rights and obligations hereund...