background image

HARDWARE GUIDE

AG-811

CCMS gateway with timer, 3 outputs and LTE

           

www.atreyo.in

  ARAD/AG-811/HG/2021/02 – preliminary

 Page |  1

Содержание AG-811

Страница 1: ...HARDWARE GUIDE AG 811 CCMS gateway with timer 3 outputs and LTE www atreyo in ARAD AG 811 HG 2021 02 preliminary Page 1 ...

Страница 2: ...8 NO NC outputs 8 4 System functions 9 4 1 Schedule timers for control outputs 9 4 2 Astronomical timer for control outputs 9 4 3 SMS alerts 9 4 4 Configuration of device 9 4 5 Power supply 9 4 6 Mounting place and condition 10 5 Wiring example 11 5 1 Example 1 with 24V external power relays contractors 11 5 2 Example 2 with common 230V supply for power relays contractors 12 5 3 Example 3 with sep...

Страница 3: ...it is needed to control accurate on off time with support of Modbus devices It can be controlled remotely from server or via SMS or also work in stand alone mode The AG 811 has advance alert option with 10 mobile number list for SMS alerts In superCap models there is power backup with power loss alert facility 1 1 Features LTE and GSM connectivity GNSS for accurate time and location 3 independent ...

Страница 4: ...Hardware Guide AG 811 2 Layout 2 1 Layout and connector functions Top panel view Connector panel view www atreyo in ARAD AG 811 HG 2022 02 preliminary Page 4 ...

Страница 5: ...y Antenna LTE and GNSS All necessary pluggable connectors DIN rail clamp with screws 2 4 Optional accessory High gain LTE antenna panel mount combo antenna APS 10W24 3 phase power supply 24V 1A adapter power supply www atreyo in ARAD AG 811 HG 2022 02 preliminary Page 5 ...

Страница 6: ...rking condition permanent ON POWER Low high voltage supply blinking 2 times per second ACT Normal working condition blinking every 1 second Serial RX and TX data indication of RS485 blinking on data transfer Inputs Input 1 and 2 high level indication ON if input high Outputs Out 1 3 ON ON on output ON 3 3 LAN and PoE The LAN interface use standard RJ45 8 pin connector with LED indicators The conne...

Страница 7: ...ange It is possible to directly send and receive any value of register from server Please follow proper connection of A and B signals from device to A and B signals in power meter If the polarity is reversed there will be no data transmission All modbus configuration like baud rate parity address available in internal website The device provide on board 120Ω termination resistor for RS 485 port 3 ...

Страница 8: ...C Inputs support only DC signal with proper polarisation The input digital high is from 3 5V to Vmax and digital low from 0 to 2V Inputs can be controlled also by open collector circuit with common positive The input resistance is approx 2 7k The input terminal diagram is as per below 1 2 digital input positive 1 2 digital input negative If by mistake reverse polarity signal is connected to input ...

Страница 9: ... IP address of device 192 168 10 50 It is necessary to make proper configuration of LAN network in laptop SMS commands Device allow to make configuration by SMS command There is option to filter allowed mobile number to make configuration String from TCP IP server By the command from server it is possible to make all configuration But initially it is necessary to set server configuration in device...

Страница 10: ...The device is dedicated to use in environment that is clean and protected from water and dust It can be used inside electrical panel boxes outdoor and without box in indoor application Mounting on standard 35mm DIN rail Device can be placed in any direction Protect device from direct sunlight and any other heat source www atreyo in ARAD AG 811 HG 2022 02 preliminary Page 10 ...

Страница 11: ...or control lighting with external high power DC24 coil relays The inbuilt relays in the device drive with 12 24V DC external relays The switches can be used for sending information to server about such cases like open the door of panel switching to manual option or any other www atreyo in ARAD AG 811 HG 2022 02 preliminary Page 11 ...

Страница 12: ...n 230V supply for power relays contractors The example with power relay contactor powered by single 230V AC In this example the separate power is provided for relays but common for all relays www atreyo in ARAD AG 811 HG 2022 02 preliminary Page 12 ...

Страница 13: ...dware Guide AG 811 5 3 Example 3 with separate power for relay contractor This example is with separate relay power Each relay from different phase www atreyo in ARAD AG 811 HG 2022 02 preliminary Page 13 ...

Страница 14: ...re Guide AG 811 5 4 Example 4 single phase direct drive This is example for direct driving the load Ensure maximum load not exceed 300W on every output www atreyo in ARAD AG 811 HG 2022 02 preliminary Page 14 ...

Страница 15: ...rks Atreyo and the Atreyo logo are registered trademarks of Atreyo Research and Development LLP All other trademarks and copyrights are the property of their respective owners 6 3 Disclaimer All dimensions mentioned in the drawings are not to scale and may vary differ due to construction contingencies and site conditions which are subject to change as may be decided by the company The specificatio...

Отзывы: