Industrial Serial Device Sever

Industrial Modbus Gateway

SE5201 / MB5201 / SE5201C / MB5201C  Series

Version 1.1

Updated in January, 2019

P/N : 89900532G

Tel: 886-3-5508137

Fax: 886-3-5508131

www.atop.com.tw

Inside the package you will find the following items:

■ Industrial Serial Device Sever x 1
■ 3-Pin Terminal Block x 1 or 5-Pin Terminal Block x 1 (Depend on model)
■ Wall mount screws  x 2
■ Installation Guide with Warranty Card x 1

Front View

3. DC Jack Power Input

4. Terminal Block Power Input

    (SE5201/MB5201 series only)

5. Reset
6. 10/100M LAN port

7. RUN LED
8. LAN LED
9. COM LED

1. COM Port - Terminal Block

2. COM Port -DB9

Top View

RUN LAN COM

7 8 9

Back View

V- V+

FG

3

4

6

5

1

2

You can then choose whether to plug in 
the other peripheral ports at this point 
or do it later depending on the actual 

location  of  the  device  or  level  of 

comfort for performing such operation.

3. 

Once the plate has been firmly put in 
place, proceed to mount the whole 

device as shown in (Fig. 3).Proceed to 
(Fig.  4)  if  you  want  to  remove  the 
device from DIN-Rail. 

4. 

Next we can then proceed to connect 

the device to the LAN (switch or PC, 
depending on the case), take care on 

using the RJ-45 connector; after this 

we can then proceed to the device’s 

settings

5. 

If you have purchased the wall mount 

kit, proceed to place the screws on the 

back of the device as show in (Fig. 1).

1. 

2.  Although internal grounding has been 

done inside, in order to ensure overall 

maximum performance and protect 

your device, it is still strongly advised 
to ground the device properly; hazard

-

ous  ESD  can  come  into  contact  and 

damage your equipment. On the power 
terminal block, there is a terminal for 
Frame Ground, you can choose 
whether to connect it to the grounding 
or you may opt to connect to the 
grounding screw next to the terminal 

block  (  the  one  chosen  should  be 
connected at all times ) (Fig. 2) 

■ The Serial Sever’s factory IP by default 

is  10.0.50.100  Web  UI  once  it  is 
connected  to  a  physical  network  (or 

using Management Utility, for more 
information on Management Utility, 

please refer to its manual). Please be 

aware that the PC needed for this 
procedure needs to be in the same 
subnet, or you may refer yourself to 

the device User’s Manual.

■ The  opening  to  the  sides  are  for  the  device’s  heat  dissipation  please  never 

obstruct or cover them with any objects or try to insert them through it.

FG V- V+

FG V- V+

1

2

1

2