Atop EMG8305 Series Скачать руководство пользователя страница 1

Industrial Unmanaged Gigabit Ethernet Switch

EMG8305 Series 

Version 0.1

Updated in July, 2016

P/N:89900496G

Inside the package you will find the following items:

■ Industrial Managed Gigabit Ethernet Switch x 1
■ Installation Guide with Warranty Card x 1

Never install or work on electrical or cabling during periods of lightning activity. 

Never connect or disconnect power when hazardous gases are present.

Warning:Hot Surface Do Not Touch. 

EMG8305 Series

Power

5

4

P1

P2

3

2

5

4

3

2

1

1

LAN

V1+

V1-

V2-

F.G.
V2+

BI_DC-

BI_DC+

BI_DA+ / Tx+

BI_DD+

BI_DD-

BI_DA- / Tx-

BI_DB+ / Rx+

BI_DB- / Rx-

1

2

5

6

3

7

4

8

1. LAN Port LED
2. PWR1 LED
3. PWR2 LED
4. 5-pin A-Coding Male of the power connector
5. 10/100/1000BaseT(X) 8-pin A-Coding Female or 8-Pin X-Coding Female

1

2
3

4

5

5

You can then choose whether to plug in the other peripheral ports at this point 
or do it later depending on the actual location of the device or level of comfort 
for performing such operation.

4. 

If you have purchased the DIN-Rail kit, Once the plate has been firmly put in 
place, proceed to mount the whole device as shown in (Fig. 4).
Proceed to (Fig. 5) if you want to remove the device from DIN-Rail. 

5. 

Next we can then proceed to connect the device to the LAN (switch or PC, 
depending on the case), take care on using the M12 connector; after this we 

can then proceed to the device’s settings

6. 

Proceed to place the screws on the back of the device as show in (Fig. 1).

1. 

 If you have the Din-rail kit, proceed to place the screws on the back of the 
device as show in (Fig. 2)

2. 

3. 

Although internal grounding has been done inside, in order to ensure overall 
maximum performance and protect your device, it is still strongly advised to 
ground  the  device  properly;  hazardous  ESD  can  come  into  contact  and 
damage your equipment. On the power terminal block, there is a terminal for 

Frame Ground, you can choose whether to connect it to the grounding or you 

may opt to connect to the grounding screw next to the terminal block ( the one 
chosen should be connected at all times ) (Fig. 3) 

2

1

2

1

2

■     The  housing  has  a  good  thermal  conductivity  material,  so  the  heat  can  be 

dissipated to the outside through the housing by conduction-convection.

Color

State

LED

Deacription

PWR1

PWR2

LAN

Green

Amber

Green

On

Off

On

Blinking

Off

On

Blinking

Off

Power is supplied through PWR1or PWR2

Power is off

Ethernet is linked at 10/100Mbps

Ethernet is active and data is being transmitted

Ethernet is not linked

Ethernet is linked at 1000Mbps

Ethernet is active and data is being transmitted

Ethernet is not linked

Отзывы: