Atop EH2316 Series Скачать руководство пользователя страница 1

Unmanaged Ethernet Switch

EH2316 Series

Version 1.0

Updated in November, 2018

P/N : 89900520G

Inside the package you will find the following items:

■ Unmanaged Ethernet Switch x 1
■ 5-Pin 5.08mm Lockable Terminal Block x 1
■ DIN-Rail Kit (Already mounted to the device) x 1
■ Wall Mount Kit Optional to purchase (include M3L5 screws*2)
■ Installation Guide with Warranty Card x 1

Front View

TOP View

Never install or work on electrical or cabling during periods of lightning activity. 

Never connect or disconnect power when hazardous gases are present.

Warning:Hot Surface Do Not Touch. RESTRICTED ACCESS AREA: The equipment 

should only be installed in a Restricted Access Area.

Indoor

Indoor

This equipment should be installed indoor and not connect directly with equipment

installed outdoor.

EH2316-2G

1. 10/100/1000 BASE-T(X) RJ45 Ports
2. 10/100 BASE-T(X) RJ45 Ports
3. PWR1 LED
4. PWR2 LED

5. Grounding Screw
6. Functional Ground

7~8. Terminal for Power 1
9~10. Terminal for Power 2

P1

1

1G

2

3

4

9

10

11

12

5

6

7

8

13

14

15

16

P2

3

1

2

2

2

2

4

F.G.

V1-

V1+

V2-

V2+

5

6

7

8
10

9

You can then choose whether to plug in the other peripheral ports at this point 
or do it later depending on the actual location of the device or level of comfort 
for performing such operation.

3. 

Once  the  plate  has  been  firmly  put  in  place,  proceed  to  mount  the  whole 
device  as  shown  in  (Fig.  3).Proceed  to  (Fig.  4)  if  you  want  to  remove  the 
device from DIN-Rail. 

4. 

Next we can then proceed to connect 
the device to the LAN (switch or PC, 
depending on the case), take care on 
using the RJ-45 connector; after this 

we can then proceed to the device’s 
settings

5. 

If you have purchased the wall mount 
kit, proceed to place the screws on the 

back of the device as show in (Fig. 1).

1. 

2. 

Although internal grounding has been 

done inside, in order to ensure overall 

maximum  performance  and  protect 

your device, it is still strongly advised 

to ground the device properly; hazard-
ous  ESD  can  come  into  contact  and 
damage your equipment. On the power 

terminal block, there is a terminal for 
Frame Ground, you can choose 
whether to connect it to the grounding 
or you may opt to connect to the 

grounding  screw  next  to  the  terminal 
block  (  the  one  chosen  should  be 
connected at all times ) (Fig. 2) 

■ The  opening  to  the  sides  are  for  the 

device’s heat dissipation please never 
obstruct or cover them with any 
objects or try to insert them through it.

F.G.

V1-

V1+

V2-

V2+

(Fig.2)

(Fig.1)

F.G.

V1-

V1+

V2-

V2+

1

2

(Fig.3)

1

2

(Fig.4)

Отзывы: