Atop ABLELink
®
Ethernet-Serial
Server GW21R
User Manual
Version 2.3
Updated on 2004/08/18
Tel: 886-3-5508137 Fax: 886-3-5508131
www.atop.com.tw
Страница 1: ...Atop ABLELink Ethernet Serial Server GW21R User Manual Version 2 3 Updated on 2004 08 18 Tel 886 3 5508137 Fax 886 3 5508131 www atop com tw...
Страница 2: ...ansmitted stored in a retrieval system or translated into any human or computer language in any form by any means in whole or in part without the prior express written consent of Atop Technologies Inc...
Страница 3: ...rference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his ow...
Страница 4: ...3 5 1Setup of a virtual COM driver 30 3 5 2 Virtual COM communication 31 4 SNMPSETUP 35 4 1 SNMP NETWORK MANAGEMENT PLATFORM 35 4 2 USING NETWORKVIEW AS AN EXAMPLE 35 5 START WRITINGYOUR OWNAPPLICATI...
Страница 5: ...UN LED 46 APPENDIX B UPGRADE SYSTEM SOFTWARE 47 B 1 UPGRADE PROCEDURES 47 B 2 CRITICAL ISSUES OF UPGRADING 48 B 3 ERROR MESSAGES 48 APPENDIX C HARDWARE CONFIGURATION 49 C 1 DISABLE SYSTEM FIRMWARE 49...
Страница 6: ...atever data received from RS 232 RS 485 to TCP UDP port then connect devices to the Ethernet network via a single application program or multiple application programs Many control devices provide the...
Страница 7: ...User manual Version 2 3 ABLELink Ethernet Serial Server GW21R Copyright 2004 Atop Technologies Inc All rights reserved Designed in Taiwan 6 54...
Страница 8: ...User manual Version 2 3 ABLELink Ethernet Serial Server GW21R 2 Application Connectivity Copyright 2004 Atop Technologies Inc All rights reserved Designed in Taiwan 7 54...
Страница 9: ...User manual Version 2 3 ABLELink Ethernet Serial Server GW21R Copyright 2004 Atop Technologies Inc All rights reserved Designed in Taiwan 8 54...
Страница 10: ...owing table Property Default Value IP Address 10 0 50 100 Gateway 10 0 0 254 Subnet Mask 255 255 0 0 User Name Admin Password Null COM 1 9600 None 8 1 No flow control COM 2 9600 None 8 1 No flow contr...
Страница 11: ...ss of GW21R using system default user name admin and default password null 2 Only TCP IP packet with destination port number 1 will lead GW21R to reboot and change the IP address 2 3 Auto IP A DHCP se...
Страница 12: ...associated with serial port COM1 respectively After your application program connects to the TCP port 4660 of GW21R data being sent to this TCP connection from your application program are transparen...
Страница 13: ...please refer to Appendix D Configuration Utility 3 2 Configuration set by Telnet utility You can use Telnet utility to change configuration settings of GW21R To do so please do the following Log in to...
Страница 14: ...ithin 1 minute Telnet will be terminated automatically 2 The changes of networking parameters will take effect only when you exit and restart GW21R 3 Select 1 from Input choice and enter 0 4 to enter...
Страница 15: ...nformation of GW21R including IP and MAC address SNMP information kernel and AP version and connection status of the device Networking Select 2 from Input choice and enter 0 4 to enter Networking page...
Страница 16: ...ess subnet mask gateway IP address and SNMP information of GW21R Please notice that any setting change made on this page won t take effect until you restart the device Change the password 1 Select 3 f...
Страница 17: ...ord fields Note You can press the default key of product to reset password to the default value COM1 Setup Select 4 from Input choice and enter 0 4 the following screen appears The page gives you the...
Страница 18: ...ver and the local port is 4660 IP filter is disabled by default if IP filter is enabled only source IP 10 0 0 154 can connect to GW21R Note IP filtering function is disabled if setting FILTER_IP to 0...
Страница 19: ...ELink Ethernet Serial Server GW21R Configure GW21R as UDP client the local port is 4660 the destination IP is 10 0 29 254 destination port is 666 Copyright 2004 Atop Technologies Inc All rights reserv...
Страница 20: ...f COM1 the following screen appears you can then give the COM port alias name set the baud rate and parity determine number of data bit and stop bit and decide if you want to use flow control and the...
Страница 21: ...rt serial data buffer is enabled meaning that when TCP IP Ethernet connection is broken serial data collected from serial device will be kept in GW21R once TCP IP connection is resumed the serial data...
Страница 22: ...ial communication It can prevent packets from being cut thus keep the packets complete GW21R provides two ways of parameter setting as inter character timer and terminator By default packet delimiter...
Страница 23: ...2 3 ABLELink Ethernet Serial Server GW21R You can also choose character pattern as the packet delimiter indicated in the following figure Copyright 2004 Atop Technologies Inc All rights reserved Desig...
Страница 24: ...4 Wait the device finishing the initialize Listen to the beeper sound 5 Send the character Z or z three times within two seconds 6 Once hyper terminal is connected type in username and password then...
Страница 25: ...0 100 2 The following authentication screen appears Please type in user name and password then click on OK The user name is admin and password is null by default 3 The following overview page appears...
Страница 26: ...rd field input the new password in the New Password and the Verified Password fields and then click on Save Configuration to update the password Note You can press the default key of product to reset...
Страница 27: ...nfiguration by clicking on DHCP to obtain auto IP address gateway and subnet mask information Enable SNMP by checking Enable fill in network identification information under SNMP field and click on th...
Страница 28: ...COM1 Setup Click on the COM1 link and the following screen appears Fill in COM1 parameter information under COM1 field then click on Save Configuration button to save the changes Copyright 2004 Atop...
Страница 29: ...enabled only source IP 10 0 29 11 can connect to GW21R Configure GW21R as TCP client the destination IP is 10 0 29 11 destination port is 4660 Pair Connection In the case of the serial connection is e...
Страница 30: ...s UDP mode Local port is 4660 destination IP is 10 0 29 254 and destination port is 4660 1 Click on Save Configuration to save the changes 2 If the update is successful the following screen appears Co...
Страница 31: ...t COM5 Virtual COM Port COM6 Virtual COM Port OS Driver Level COM256 Virtual COM Port PC HUB TCP IP Network Serial Line Serial Device 1 Serial Line Serial Device 2 Serial Line Serial Device 3 Serial L...
Страница 32: ...ports Uninstalling 1 From Windows Start menu select Setting Control Panel Add Remove Programs 2 Select Serial IP for ATOP in the list of installed software 3 Click the Add Remove button to remove the...
Страница 33: ...problems occurred Or you can enable Virtual COM through telnet configuration by setting COM1 as TCP server and type in the local port number for COM1 then enable virtual COM as shown in the following...
Страница 34: ...st use the Select Ports button Each COM port has its own settings When you click on a COM port the Control Panel display changes to reflect the settings for that COM port Note When you change settings...
Страница 35: ...he serial server using the settings you have provided If the Log display does not show errors click the Use Settings button in the wizard which makes the recommended settings effective and returns you...
Страница 36: ...compact network management tool from NetworkView Software Inc www networkview com It discovers all TCP IP nodes in a network using DNS SNMP and ports information and documents with printed maps and r...
Страница 37: ...ollowing diagram Double click on the device icon to display information about the device including IP Address Company SysLocation Max 15 characters SysName Max 9 characters and types etc Note 1 The Ne...
Страница 38: ...ion utility 5 2 Running The Sample Program Sample programs written in VB and VC included in package are provided for your reference source codes are also included Test program can be found in the prod...
Страница 39: ...GW21R Copyright 2004 Atop Technologies Inc All rights reserved Designed in Taiwan 38 54 Status Status 4 3 2 1 5 2 2 TCPTEST2 in Visual C To start the program please type in the following command in t...
Страница 40: ...send binary data in hex format with a leading character For example 00 and FF represent ASCII code 0 and 255 respectively You can also use modem to connect to the serial server Command AT Od sends st...
Страница 41: ...ility ping Command From Windows Start menu select Run and type in ping TCP Server IP address If the connection is established the Reply messages are displayed otherwise it will indicate Request timed...
Страница 42: ...connected C The system is configured as a TCP Client and not yet connected U The system is configured as an UDP A The TCP Server and is connected B The TCP Client and is connected For example s means...
Страница 43: ...Port Communication Two serial ports RS 232 or RS 485 is selectable RS 232 EIA RS 232C standard Full Duplex 9 pin Male D type RS 485 2 4 wires Half Full duplex 9 pins Male D type Parameters 1 Baud rate...
Страница 44: ...ws 95 98 2000 NT XP 2003 are provided for configuring settings Internal Buffer Size TCP receiving buffer size 8K bytes TCP transmitting buffer size 16K bytes RS 232 RS 485 receiving buffer size 4K byt...
Страница 45: ...N A N A 8 CTS DATA RXD 9 RI N A reserved for Atop devices TXD A 3 2 Ethernet Port RJ 45 1 Category 5 UTP cable 8 core wire 2 RJ45 Connector 3 RJ45 Pin Assignment Pin Assignment 568A Definition 568B D...
Страница 46: ...red Memory problem return service is required 5sec Startup OK but AP firmware is disabled 5sec Startup OK and AP firmware is enabled Table 1 Buzzer Message A 4 2 LAN LED Message Description LED Off No...
Страница 47: ...RUN LED Message Description LED on Jumper JP1 pin1 and pin2 are short to disable AP firmware in the flash memory LED blinking rate 0 5Sec AP firmware is running Table 4 RUN LED Message Copyright 2004...
Страница 48: ...e command ping or monitor exe utility program to verify their availability 2 Prepare the download tool Execute the utility program download bat and press any key to edit its configuration file dapdl c...
Страница 49: ...s Normally it takes around 10 seconds to complete the programming process If an error occurs during the programming process GW21R will clear the corresponding memory and the system remains intact of w...
Страница 50: ...e 6 Close the case and continue your operations Please refer to Figure C 1 Component Side of GW21R main board for jumper JP1 location C 2 Choose Type of COM Ports GW21R main board version 1 4 COM port...
Страница 51: ...rd v1 4 2 Monitor exe utility can be used to demonstrate COM ports properties 3 2 1 3 2 1 COM2 COM1 JP9 JP14 For COM2 JP3 JP8 For COM1 2 1 JP1 Figure C 1 Component side of GW21R main board v1 4 Copyri...
Страница 52: ...ional Devices You may do the following steps to detect devices currently available on the network 1 Start monitor exe utility program 2 Select an item from the Broadcast IP list 3 Specify a number in...
Страница 53: ...as shown in Figure D2 Figure D2 Configuration dialog box 3 After you click the Configure Now button the target device will return an ACK message indicating the modification is successful as shown in...
Страница 54: ...of devices this utility program detected Retry Specify the number of times that an Invite request is re sent Locate Locate the specified device Reset Reset the selected device Config Configure the sel...