Using AVR Studio
5-6
AVR STK500 User Guide
1925C–AVR–3/03
Figure 5-6.
Board
5.3.5.1
VTARGET
VTARGET controls the operating voltage for the target board. Through the use of the
slide bar or the text box, this voltage can be regulated between 0 and 6.0V in 0.1V incre-
ments. Please refer to the device datasheet to find the specified voltage range for the
selected device. Both voltages are read by pressing the “Read Voltages” button, and
written by pressing the “Write Voltages” button.
The physical connection of the VTARGET voltage is shown in Figure 3-22 on page 3-16.
5.3.5.2
AREF
AREF controls the analog reference voltage for the ADC converter. This setting only
apply to devices with AD converter. Through the use of the slide bar or the text box, this
voltage can be regulated between 0 and 6.0V in 0.1V increments. Please refer to the
device datasheet to find the valid voltage range for the selected device. Both VTARGET
and AREF are read by pressing the “Read Voltages” button, and written by pressing the
“Write Voltages” button.
It is not possible to set AREF to a higher voltage than VTARGET because this will per-
manently damage the AVR.
The physical connection of the AREF voltage is shown in Figure 3-24 on page 3-18.
Содержание AVR STK500
Страница 1: ...STK500 User Guide ...
Страница 2: ......
Страница 38: ...Hardware Description 3 28 AVR STK500 User Guide 1925C AVR 3 03 ...
Страница 40: ...Installing AVR Studio 4 2 AVR STK500 User Guide 1925C AVR 3 03 ...
Страница 52: ...In System Programming of an External Target System 6 2 AVR STK500 User Guide 1925C AVR 3 03 ...
Страница 56: ...Technical Support 8 2 AVR STK500 User Guide 1925C AVR 3 03 ...
Страница 60: ...Appendix A 10 2 AVR STK500 User Guide 1925C AVR 3 03 ...