Setting Up the AT91EB01 Evaluation Board
3-2
AT91EB01 Evaluation Board User Manual
Figure 3-1.
Layout of the AT91EB01 Evaluation Board
3.4
Jumper Settings
LK2 is used to select the clock frequency and by default is set to 32,768 MHz. For more
information about this jumper and also the various surface mount links see “Appendix A
- Configuration Links and SRAM Bank 1” on page 6-1.
3.5
Powering Up the
Board
DC power is supplied to the board via the 2.1mm socket (J4) shown below in Figure 1.
The polarity of the power supply is not critical. The minimum voltage required is 7V.
The board has a voltage regulator pro3.3V. The regulator allows the input volt-
age to be from 7V to 9V. When you switch the power on, the red LED marked "POWER"
will light up. If it does not, switch off and check the power supply connections.
positive (+)
or
negative (-)
2.1 mm connector