AT-UHD-HDVS-300-KIT
40
The Web GUI
Auto Power Off Timer
Sets the time interval, in seconds, between when the loss of A/V signal is detected and when the “Display Off”
command is sent. Range: 5 seconds to 1 hour.
Display Warm Up Timer
Sets the time interval, in seconds, between when the display is powered on and when the
POWER
button on the
front panel will be locked. Range: 0 to 300.
Volume Repetition Rate
Enter this volume repetition rate in this field. This field defines how fast the volume is changed, when holding down
the volume buttons on the front panel. Higher values will slow the rate at which the volume is changed.
Power
Click this
On
button to power-on the unit. Click the
Off
button to power-off the unit.
Output Volume
Click the
+
and
-
buttons to increase or decrease the volume, respectively. Click the
Mute
button to mute the audio
output.
The AT-UHD-HDVS-300-KIT can control two separate IP devices on a network. However, only one device can be
controlled at a time. Specify the IP settings in this section.
Remote IP address
Enter the remote IP address in this field.
Remote Port
Enter the remote listening port in this field.
UDP Local Port
Enter the local UDP listening port in this field.
Send with
Click this drop-down list to select either the TCP or UDP protocol, when sending commands.
Display Auto Power On
Sends the command to power-on the display when an A/V signal is detected. Click the drop-down list and select
On
to enable this feature.
Display Auto Power Off
Sends the command to power-off the display after the
Auto Power Off Timer
has expired. Click the drop-down list
and select
On
to enable this feature.
Lamp Cool Down Timer
Sets the cool-down interval, in seconds, before the projector can be powered-off. During this time interval, the
projector will not accept any commands until the “power off” command has been processed and the projector lamp
has completed the cool-down cycle. Range: 0 to 300.
Display Auto Power On
Sends the command to power-on the display when an A/V signal is detected. Click the drop-down list and select
On
to enable this feature.
Display Auto Power Off
Sends the command to power-off the display after the
Auto Power Off Timer
has expired. Click the drop-down list
and select
On
to enable this feature.
Lamp Cool Down Timer
Sets the cool-down interval, in seconds, before the projector can be powered-off. During this time interval, the
projector will not accept any commands until the “power off” command has been processed and the projector lamp
has completed the cool-down cycle. Range: 0 to 300.