Atlas F6-MF Скачать руководство пользователя страница 1

 

– 9 – 

AtlasSound.com

Specifications are subject to change without notice.

Owner’s Manual

F6-MF

Multi-Impedance Modular Amplifier

1601 Jack McKay Blvd. • Ennis, Texas 75119  U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

FM250-4 and FM250-70 Module Features

1.  Module Status Indicators

 

Note:

 They also parallel Status LED on the front panel of the F6-MF panel. 

 Ready

 

  This LED will illuminate Green when an FM250 power module is installed on the appropriate channel and the F6-MF is 

turned on.

 

Signal

 

  The channel Signal LED will illuminate Green when the FM250 amplifier output signal produces a minimum 1 Watt 

output. 

 

Limit

 

  The Limit LED will illuminate Yellow under load conditions. If the FM250 function switch is set to Limit then the LED 

acts as a maximum level indicator. If the FM250 channel Limit function is off, the LED reacts as a Clip indicator. Also, 

under Low Impedance loads, this LED serves as a current Limit indictor.

 

Protect

 

  The Protect LED will illuminate Red during one the following conditions. No output will occur while this LED is 

illuminated. It will reset itself after the condition has been corrected.

   

1) 

 

Shorted speaker output.

   

2) 

 

Thermal Shut Off. The Temp F6-MF TEMP LED will also be illuminated.

   

3) 

 

 Current Overdrive. If the amplifier channel is driving too low of a speaker load.

2. Speaker Connections

A removable Phoenix/Euro Block type connector is supplied to connect your speakers to the FM250 amplifier module. It is 

recommended to use 16-gauge wire or lower for connection to the speakers. 

Note:

 Do not overload the amp by connecting too many 

speakers to the amp.

Protect

Limit

Signal

Ready

Speaker Output

Class 2 Wiring

4

Ω

FM250 - 4

250W @ 4

Ω

Protect

Limit

Signal

Ready

Speaker Output

Class 2 Wiring

70V

FM250 -70

250W @ 70V

Отзывы: